show rmon statistics

show rmon history

System Usage Notes

Title

Non-Present Ports.

Ports are not removed
automatically from an IGMP
group by removing them from
the VLAN.
Only management stations
with super community access
can set rndAlarmEnabling.
System Firmware Version 2.0.0.20
PowerConnect 3424/3448 Release Notes
Oversize Packets – Number of oversized packets (over 1632 octets)
received on the interface since the device was last refreshed.
Jabbers – The number of packets received during this sampling interval
that were longer than 1632 octets (excluding framing bits but including
FCS octets), and had either a bad Frame Check Sequence (FCS) with an
integral number of octets (FCS Error) or a bad FCS with a non-integral
number of octets (Alignment Error).
Dropped Events – counter is not supported.
(and not as indicated)
Oversize Packets – Number of oversized packets (over 1632 octets)
received on the interface since the device was last refreshed.
Jabbers – The number of packets received during this sampling interval
that were longer than 1632 octets (excluding framing bits but including
FCS octets), and had either a bad Frame Check Sequence (FCS) with an
integral number of octets (FCS Error) or a bad FCS with a non-integral
number of octets (Alignment Error).
Dropped Events – counter is not supported.
(and not as indicated)
Description
Certain ports in the device may have a status of "non-present ports".
These include:
- The stacking ports can be presented as user ports, in the event that
the device is a standalone (and not a stack unit). Therefore, these
ports are treated as "non-present".
- FE ports 25-48 of a 24-port device are considered "non-present"
ports, so that in the event of hot insertion of a 48-port device in place
of the 24-port device, the ifindexes of the GE ports remain consistent.
Ports are not removed from IGMP group configuration, when they are
removed from the VLAN. Ports are added to the IGMP group by using
the command bridge multicast address ip-address add interface.
Ports must be proactively removed from the IGMP group by using the
command bridge multicast address ip-address add interface.
Only management stations with super community access can set
rndAlarmEnabling.It is not possible to set rndAlarmEnabling when rw
community is defined for the Default View.