Dell PowerConnect B-DCX-4S Backbone Процедура замены - Страница 13
Просмотреть онлайн или скачать pdf Процедура замены для Переключатель Dell PowerConnect B-DCX-4S Backbone. Dell PowerConnect B-DCX-4S Backbone 16 страниц. Power supply and filler
panel
Также для Dell PowerConnect B-DCX-4S Backbone: Процедура замены (6 страниц)
switch:admin>
2. Determine any differences between the information in the "SANafter.txt" file and the information in the
"SANbefor.txt" file created earlier. In particular, look for differences in the following:
•
Device types
•
Number of devices
•
ISL and port states
•
Number of switches in the fabric
3. Resolve any issues or unintentional changes to the PowerConnect B-DCX-4S or fabric.
•
If there are any mechanical problems, try reseating the associated component.
•
If the configuration information is not correct for the PowerConnect B-DCX-4S, modify as required. If
necessary, the configuration saved before the replacement can be downloaded using the configDownload
command.
The configDownload command can be entered through a Telnet or serial session, but the PowerConnect
B-DCX-4S must have an Ethernet connection to the server name or IP of the host for the download process
to complete. For more information, refer to the help configdownload command or the Fabric OS Command
Reference.
switch:admin> configdownload
Server Name or IP Address [host]: 123.123.123.123
User Name [None]: Admin24
File Name [config.txt]: config-switch.txt
Password: xxxxxxxx
download complete
switch:admin>
•
If other issues exist, contact your support provider.
Cable routing table
Table 2
is a 48-port template for a cable-routing table. Expand the table for the number of ports in the PowerConnect
B-DCX-4S.
TABLE 2
Cable routing table for PowerConnect B-DCX-4S (48 ports shown)
Slot/port
Cable labels
Slot
Port
Switch end
0
1
2
3
4
5
6
7
PowerConnect B-DCX-4S Chassis Replacement Procedure
53-1001800-01
Connected device
Device end
Slot/port of device
13