Table 2
provides the chassis slot numbers into which you must install the modules. Markings for the chassis slots
appear at the base of the slots.
TABLE 2
PowerConnect B-RX Series installation
PowerConnect B-RX Series
module
Management modules
Interface modules
Switch fabric modules
1.
Each PowerConnect B-RX Series chassis ships with the required switch fabric modules installed.You must purchase an additional
switch fabric element if you want your chassis equipped for redundancy.
CAUTION
If you do not install a module in a slot, you must leave the slot blank installed in the slot. If you run the
PowerConnect B-RX Series chassis with an uncovered slot, the system may overheat.
If you are installing a redundant management module, refer to the appropriate configuration guide for your product
for information about how the redundant module works, optional software configurations that you can perform, and
how to manage the redundancy feature.
Before installing a module in the PowerConnect B-RX Series chassis, have the following on hand:
An ESD wrist strap with a plug for connection to the ESD connector on the PowerConnect B-RX Series chassis.
DANGER
For safety reasons, the ESD wrist strap should contain a 1 meg ohm series resistor.
A large flat-head screwdriver.
Follow the steps given below to install a module in the PowerConnect B-RX Series chassis.
NOTE
The installation instructions for installing modules in the following steps are exactly the same for interface,
management, and switch fabric modules.
1. Put on the ESD wrist strap and ground yourself by inserting the plug into the ESD connector on the chassis front.
2. Remove the module from its packaging.
3. With the ejectors in the outward position, insert the module into the appropriate chassis slot and slide the card
along the card guide until the ejectors on either side of the module move close to the module front panel. Refer
to
Figure 8
(four-slot chassis),
PowerConnect B-RX Series Getting Started Guide
53-1001682-03
Chassis slot number (four-slot and eight-slot chassis)
Active module – M1 (left).
Redundant module – M2 (right).
1 – 4 (four-slot chassis)
1 – 8 (eight-slot chassis)
1
SF1 – SF3
Figure 9
(eight-slot chassis), and
Chassis slot number (16-slot chassis)
Active module – M1 (upper).
Redundant module – M2 (lower).
1 – 16 (16-slot chassis)
1
SF1 – SF4
Figure 10
(16-slot chassis).