Dell S50V Краткое руководство по эксплуатации - Страница 12

Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Переключатель Dell S50V. Dell S50V 25 страниц. Switches

Power Supplies

On both the S50N and S50V, either the AC or DC power supplies alone are
sufficient to power the switch. When both AC and DC power supplies are
connected, they act in roughly a 60%/40% load-sharing mode.
WARNING: To prevent electrical shock, make sure the system is grounded
properly. If you do not ground your equipment correctly, excessive emissions
may result. Use a qualified electrician to ensure that the power cables meet
your local electrical requirements.
Fans
Ventilation is side-to-side, with six fans on the left side of the switch as you face
the PSU side.
The fan speed increases when the temperature reaches 72 degrees C, and
decreases to normal speed when the temperature falls to 57 degrees C. The
switch never intentionally stops managing traffic.
Status logging is identified by unit in the system log.
Fan replacement in the field is not offered as an option.

Specifications

Chassis Physical Design

Parameter
Height
Width
Depth
Chassis weight with
factory-installed
components
Rack clearance
required
10
Installing the Hardware
S50N and S50N-DC
Specifications
1.73 inches (4.4 cm)
17.32 inches (44.0 cm) (19"
rack-mountable)
16.73 inches (42.5 cm)
(standard 1 rack unit)
14.41 pounds (approx.) (6.54
kg)
Front: 5-inches (12.7 cm)
Rear: 5-inches (12.7 cm)
S50V Specifications
1.73 inches (4.4 cm)
17.32 inches (44.0 cm) (19"
rack-mountable)
16.73 inches (42.5 cm)
(standard 1 rack unit)
14.41 pounds (approx.) (6.54
kg)
Front: 5-inches (12.7 cm)
Rear: 5-inches (12.7 cm)