EarthQuake Cinenova Grande Руководство пользователя - Страница 12
Просмотреть онлайн или скачать pdf Руководство пользователя для Усилитель EarthQuake Cinenova Grande. EarthQuake Cinenova Grande 16 страниц. 5/7 channel power amplifier
Adjusting The Filters
Filter Settings
Each channel - monaural block - of the
Cinénova Grande amplifiers comes
equipped with a fully buffered variable filter
(range: 20 Hz to 5000 Hz). Once a crossover
point is selected, the block can be run in low
pass or high pass configuration, simply by a
flick of a 3-way switch; the filter can be
bypassed by setting the switch to the full
range position.
12
REFER TO THE FOLLOWING ILLUSTRATIONS FOR FILTER SETTING:
Knob In 9 O'clock
Position
+6.0
Filter @ 55Hz
+3.0
0.0
-3.0
-6.0
55Hz
Knob In Min
Position
+6.0
Filter @ 20Hz
+3.0
0.0
-3.0
-6.0
20Hz
Knob In 12 O'clock
+6.0
Position
Filter @ 360Hz
+3.0
0.0
-3.0
-6.0
360Hz
Knob In 3 O'clock
+6.0
Position
Filter @ 5kHz
+3.0
0.0
-3.0
-6.0
5kHz
Earthquake Sound