Allied Vision Alvium Руководство - Страница 8
Просмотреть онлайн или скачать pdf Руководство для Аксессуары Allied Vision Alvium. Allied Vision Alvium 18 страниц.
9. Instructions for Prosilica GT cameras – TCG
At delivery, sensors of TCG cameras are protected by the cover glass fixed by adhesive tapes. This section
instructs on removing these tapes and the cover glass, starting to disassemble the camera in order to get
access to the sensor.
Damage to the camera electronics and sensor
• Work in a dust-free environment (class 100 or better) with humidity according
• Observe notes for
• Follow the instructions thoroughly.
About the following instructions
The instructions consist of multiple steps. We recommend you to read the
instructions first to get an orientation on camera preparation.
For Prosilica GT Extended Format housing cameras, start with
Format housing cameras
on page 8.
For Prosilica GT Large Format housing cameras, start with
housing cameras
on page 10.
9.1. Disassembling Prosilica GT Extended Format housing cameras
1. Power off and unplug the camera.
2. With a water resistant ink pen, draw a line (a) across the joint between front assembly and body
assembly. This will serve as an index to reassemble the camera in correct orientation.
3. Loosen and remove the four M2 x 8 socket head cap screws of the front assembly.
Figure 8: Removing the four M2 x 8 socket head cap screws of the front assembly
4. Detach the front assembly (b) from the body assembly (c).
to ESD requirements.
3.1. Electrostatic discharge (ESD)
a
c
b
Figure 9: Detaching the front assembly
Page 8 of 18
Preparing Cameras without
NOTICE
on page 1.
9.1. Disassembling Prosilica GT Extended
9.2. Disassembling Prosilica GT Large Format
Sensor Cover Glass