Technical data
Standard voltage (CH, DK only)
Frequency
Total rated load
Fuse rating (B trip rating according to EN 60898)
Supply lead min. cross-section
Supply lead without plug for hard-wired connection
Length of supply lead
Standard voltage (B only)
Frequency
Total rated load
Fuse rating (B trip rating according to EN 60898)
Supply lead min. cross-section
Supply lead without plug for hard-wired connection
Length of supply lead
Alternative voltage (convertible)
Total rated load
Fuse rating (B trip rating according to EN 60898)
Supply lead min. cross-section
Standard voltage (N only)
Frequency
Total rated load
Fuse rating (B trip rating according to EN 60898)
Supply lead min. cross-section
Supply lead with plug
Length of supply lead
Standard voltage (AUS only)
Frequency
Total rated load
Fuse rating
Supply lead min. cross-section
Supply lead with plug
Length of supply lead
Standard voltage (CDN only)
Frequency
Total rated load
Fuse rating
Supply lead min. cross-section
Supply lead without plug for hard-wired connection
Length of supply lead
Standard voltage (J only)
Frequency
Total rated load
Fuse rating
Supply lead min. cross-section
Supply lead with plug
Length of supply lead
C o l d w a t e r ( K W )
Permissible water flow pressure
Required flow rate (cold water connection only)
Required flow rate (with additional hot water connection)
Average water consumption (60°C standard programme)
Connection to be provided on site, external thread according to DIN 44991
Connection hose ½" with ¾" threaded union
Connection hose length
= standard, = optional, + = only on request, - not available
10 144 240 / 01
PW 5065 AV
PW 5065 LP
3N AC 400 V
Hz
-
50
kW
-
4.8
A
-
3 x 10
mm²
-
5 x 1.5
-
mm
-
2000
-
2N AC 400 V
Hz
-
50
kW
-
5.5
A
-
2 x 16
mm²
-
4 x 2.5
-
mm
-
2000
-
1N AC 230
kW
-
2.85
A
-
1 x 16
mm²
-
3 x 2.5
1N AC 220-240 V 1N AC 220-240 V
Hz
50
50
kW
2.95 - 3.45
2.95 - 3.45
A
3 x 16
3 x 16
mm²
3 x 1.5
3 x 1.5
mm
2000
2000
-
1N AC 230 V
Hz
-
50
kW
-
2.85
A
-
1 x 16
mm²
-
3 x 1.5
-
mm
-
2000
-
2 AC 208 V
Hz
-
60
kW
-
4.0
A
-
2 x 20
mm²
-
4 AWG10
-
mm
-
2000
-
1N AC 200 V
50 – 60
Hz
-
kW
-
3.7
A
-
1 x 20
mm²
-
3 x 2.75
-
mm
-
2000
kPa
100 - 1000
100 - 1000
l/min
11
11
l/min
10
10
l/h
36
36
¾"
¾"
Inch
mm
1550
1550
en - GB
9