6.3.2 Advanced menu
Lp.o. Partial opening
Partial opening can be performed only starting from closed. The parameter sets the opening like a percentage of the total stroke of the first wing.
tp.r. Pre-flashing time
Pre-flashing before each movement in both directions, tp.r. seconds of pre-flashing
fC.y. Courtesy light settings
The control unit has 4 different functionings for courtesy light:
fC.y. = 0 the light switches off at the end of a movement after tC.y. seconds
fC.y. = 1 open gate light - the light switches off immediately when the gate reaches the closed position
tC.y. Courtesy light timer
Courtesy light activation timer
de.a. Dead man
During dead man functioning mode the gate moves only with a permanent command.
The enabled commands are OPEN and CLOSE. SS and PED are disabled. During dead man functioning all the automatic movements are disabled,
like short or total inversions. All safety devices are disabled except for STOP.
Ha.o. Water-hammer in opening phase
This functioning is used with an electrical lock. The gate before opening closes shortly on the mechanical stop with the electrical lock activated, to
ensure the correct declutching. The parameter is the time of pressure on the mechanical stop before opening, settable from 0.1s to 10 s.
The sequence done by the control unit before opening is the following:
preventive activation of the electrical lock [1,5s]. ATTENTION! Necessary enable electrical lock on the advanced menu parameter:
motor activation in closing with maximum torque. The duration of this phase is setted by the parameter Ha.o.
inversion of direction with another 2 seconds of activation of the electrical lock. Necessary enable electrical lock on the advanced menu
elm
elm
elm
elm
parameter:
Ha.c. Water-hammer in closing phase
This functioning is used with an electrical lock. When the gate reaches the closing mechanical stop the control unit perform a strong pressure,
Ha.c. seconds long, to ensure the locking of the electrical lock. Necessary enable the electrical lock from the advanced menu parameter
(if used)
mp.r. Time of pressure in closed position for hydraulic motors
This function is used to keep high the pressure of hydraulic motors, done only with closed gate, the control unit performs 1 minute of closing every
mp.r. minutes to keep high the pressure into the motors and the correct closed position.
tr.S. Viewing of the memory position for a single transmitter
With the item of the menu tr.S. it is possible to view the memory location in which a transmitter is memorized.
To perform the function, move to tr.S. and then confirm by pressing the button MENU. Keep pressed MENU button untill the display will show
then release the button.
At this point press a button of the memorized transmitter (it does not active any command). The display shows:
the memory location for 2 seconds, if is memorized;
the written
After 2 seconds the display returns to the screen
To exit from the function, press MENU button. Otherwise after 15 seconds without transmission, the control unit exits from the function and shows the
written
tr.C. Cancellation of a single transmitter
With the item of the menu tr.C. it is possible to delete a single transmitter from the memory.
To perform the function, move to tr.C. and then confirm by pressing the button MENU. Keep pressed MENU button untill the display will show 0, then
release the button. Select the memory location of the transmitter. Press and keep pressed MENU button untill the display will show
release the button.
To exit from the function, press MENU button. If the display shows the written
position or disconnected memory).
de.f. Restore default settings
With this parameter it is possible to restore the default settings of the control unit. The reset will restore all the parameters of the base and advanced
menu, but doesn't modify the learnt strokes, the directions of motors and the transmitters.
Move to de.f. then keep pressed MENU button until the display shows 0, release the button. Press again and keep pressed MENU button, the display
will show a count down d80,d79,...,d01 ,don't release the button until the display showns
tr.f. Erasing of all transmitters
With this parameter it is possible to erase all the transmitters learnt.
Move to tr.f. then keep pressed MENU button until the display shows 0, release the button. Press again and keep pressed MENU button, the
display will show a count down d80,d79,...,d01 ,don't release the button until the display showns
ELM. Electrical Lock mode
Elm = 0 disable
Elm = 1 The electrical lock is activated when the automation performs an opening movement.
Elm = 2 The electrical lock is activated when the automation performs an opening movement. In the opening phase it is activated with a safety
advance time of 1.5 seconds.
Elm = 3 In case of use of magnetic electric lock, always active when the gate is closed (except when the motor is in pressure in closed position),
disable when the gate is not closed.
6-1622176
rev.05
01/03/2019
for 2 seconds, if is not memorized.
ITA
and it will be possible to perform this function with another transmitter.
, there are problems with the memory (for example empty
ENG
FRA
ESP
DEU
POR
elm = 2
elm = 2
elm = 2
elm = 2
elm
elm
elm
elm
, then
9 / 12