16. Magnetical loop connections
Closing loop: the control unit is provided with an input conceived for a closing magnetical loop, the control units will command the closing when the
contact opens, set the loop detector to provide a normal open contact, in this way when a vehicle exits an free the loop the control unit will com-
mand the closing.
Opening loop: a magnetical loop that commands the opening can be used setting the DIP switch 5 to ON, enabling the Open input, and connecting
the normal open contact of the loop detector to the Open input.
17. Control unit operation mode
The modality of intervention of the current sensor is only one. In case of intervention of the sensor in opening, the gate stops. In case of
intervention in closing , the immediate inversion is got with the total re opening of the gate.
In case the condominium function is selected, the happening of a sense in closing involves a short inversion in opening with a successive stop of
the motion until the reception of an order.
B
18. Selection of the decoding type and total deletion of the memory
In case it would be necessary to modify the decoding type (from rolling code to fix code or vice versa), or cancel all the learned transmitters,
proceed as follows:
1.
Cut off the power supply to the system
2.
Press the blue key if you want to select the fix code decoding or press the red if you want to select the rolling code decoding
3.
Keep them pressed while you give again tension
4.
Keep them again pressed until the flashing light lights on 3 times
5.
At this point release the key and wait until the flashing light lights off. The selection of the decoding and the total deletion of the memory
have not been carried out.
6-1622381
rev.2
04/02/2016
A
B
ITA
ENG
FRA
A = Running speed zone
B = Slowing down zone
The control unit is provided with standard working
time, it is still recommended to make a learning of
stroke.