Miele DA 189 Инструкции по эксплуатации и установке - Страница 24

Просмотреть онлайн или скачать pdf Инструкции по эксплуатации и установке для Вентиляционная вытяжка Miele DA 189. Miele DA 189 28 страниц. Miele ventilation hood user manual

Miele DA 189 Инструкции по эксплуатации и установке

Electrical connection

All electrical work should be
performed by a qualified electrician
in strict accordance with national
and local safety regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer can
not be held responsible for
unauthorized work.
Ensure that power to the appliance
is OFF while installation or repair
work is performed.
^ Verify that the voltage, load and
circuit rating information found on the
data plate (located behind the
grease filter), match the household
electrical supply before installing the
hood.
If there is any question concerning the
electrical connection of this appliance
to your power supply, please consult a
licensed electrician or call Miele's
Technical Service Department. See
back cover for contact information.
WARNING:
THIS APPLIANCE MUST BE
GROUNDED
Important
To increase security before the
machine is installed, it is
recommended to install a protective
switch (30 mA).
CAUTION
Connect only to a 15-ampere branch
circuit.
24
^ Remove the vapour canopy and the
grease filters from the range hood
(see "Cleaning and Care").
The electrical junction box is located on
the inside rear right of the range hood.
^ Loosen the screws and remove the
cover.
^ Feed the power line from your house
installation through the cable opening
in the casing.
^ Connect the cables to the terminal
clamps.
Important
The hood must be hard wired
accordingly:
Black/Red wire:. . . . connect to L1 (live)
White wire: . . . . . connect to N (neutral)
Green wire: . . connect to GND (ground)
^ Close up the junction box again and
re-install the grease filters and the
vapour canopy.