Miele KMR1135 G Инструкция по установке - Страница 6
Просмотреть онлайн или скачать pdf Инструкция по установке для Вентиляционная вытяжка Miele KMR1135 G. Miele KMR1135 G 21 страница.
Dimensional drawings
KMR 1134
Position
For all other Hoods, please consult with manufacturer's instructions
for required distances.
42
Dimension
min. 36"
(914 mm)
6" + + 6"
(150 mm + + 150 mm)
37" (940 mm)
36" (914 mm)
30" (762 mm)
Description
Width of cabinet opening.
In case of the presence of com‐
bustible material an additional min‐
imum clearance of 6" (each side) is
necessary. Ensure local codes are
observed.
Minimum distance between the top
of the cooking area and the bottom
of an unprotected combustible sur‐
face.
Minimum distance between the top
of the cooking area and the bottom
of the Miele Range Hood (DAR
model with DRxB XL Blower).
Minimum distance between the top
of the cooking area and the bottom
of the Miele Range Hood (DAR
model with DRxB XXL Blower).