Miele T 1526 Техническая информация - Страница 12
Просмотреть онлайн или скачать pdf Техническая информация для Сушилка Miele T 1526. Miele T 1526 42 страницы. Vented dryer
Также для Miele T 1526: Руководство по эксплуатации (28 страниц), Руководство по эксплуатации (28 страниц)
Technical Information
2.0
Installation
Do not drink the condensed water.
Keep the area around the air intake (toekick) and surrounding areas free from
lint, dust and dirt. This area should not be blocked, or it will prevent sufficient
intake of air and affect appliance operation.
Do not reach into the dryer while the drum is moving.
The appliance should be level to ensure proper operation.
A dryer can be placed on top of a Miele washer for a stacked installation. An
approved Miele stacking kit must be used.
2.1
Electrical Requirements
120/240 (208) VAC, 60Hz, 15A breaker
Dryer is equipped with a 4-wire power cord with a NEMA 14-30 plug for
connection to a NEMA 14-30 receptacle.
Note:
If you do not have a dedicated 15-amp circuit for this appliance, but have a
NEMA 14-20 or NEMA 14-30, 240VAC, 30-amp outlet, you may be able to
use a Miele Easy Installation Kit to simplify the electrical connection. For
further information, refer to the Electrical information pages in the
installation manual.
Do not cut off or remove the plug from the power cord.
2.2
Plumbing Information – Condenser Models
On condenser dryers, the option exists to have the condensed water exit the
appliance via a drain line. A suitable drain system (i.e. stand pipe) is required for
this option.
Maximum drain hose length: 10 feet
Maximum drain height: 4 feet
All condenser dryers come supplied with the following accessories to add the
drain line option. Please do not discard the parts during an installation as they
may be used at a later date.
6-foot drain hose
Hose clamp
Hose elbow
12