Importing ARC-16 Settings

AutoLoad Plus version 2.3 or later can import your ARC-16 settings using the .a16 file created by
AutoLoad 2 for the ARC-16. To import your settings, choose Import ARC-16... from the File menu in
AutoLoad Plus.
The wizard will prompt you for your ARC-16 settings file, and then allow you to choose which settings
to import. For each setting, use the Import checkbox to indicate that AutoLoad should import that
setting. Follow the onscreen instructions to complete the wizard. For more information, consult the
AutoLoad Plus Manual or help file.

Uploading New Firmware

You can load new firmware to the Plus-X Dual IP-8 Adapter using its onboard web interface. Navigate
to the IP address of the Plus-X Dual IP-8 Adapter, log on and click the Upload Firmware link. Click the
Browse button to select the firmware file, then click Upload to load the new firmware. The Plus-X Dual
IP-8 Adapter will reboot after the firmware upload is complete.
Uploading Firmware to the Plus-X Dual IP-8 Adapter
For the latest firmware updates, visit www.burk.com.

Troubleshooting

If the network connection between the Plus-X Dual IP-8 Adapter and ARC Plus is lost, the ARC Plus will
log an alarm after three minutes of network failure. The Plus-X Dual IP-8 Adapter Link LED will also turn
off. Check your network settings on both the ARC Plus and Plus-X Dual IP-8 Adapter.
Note: Plus-X Dual IP-8 Adapter events and errors are logged to the ARC Plus event list, which is accessible
by the ARC Plus front panel and from AutoPilot.
Plus-X Dual IP-8 Adapter Installation and Operation Manual Rev. B