Allmess Itron UltraMaXX M4WX Руководство по общим инструкциям - Страница 3

Просмотреть онлайн или скачать pdf Руководство по общим инструкциям для Измерительные приборы Allmess Itron UltraMaXX M4WX. Allmess Itron UltraMaXX M4WX 11 страниц. Measuring capsule heat meter screw-in heat meter

INSTALLATION INSTRUCTIONS FLOW RATE SENSOR SCREW-IN HEAT METER · CF-ULTRAMAXX
INSTALLATION INSTRUCTIONS
Flow rate sensor screw-in heat meter

CF-UltraMaXX

PACKAGE CONTENTS
• Compact heat meter
• Sealing material
• Wall mounting
• General instructions
Possibly accessories pack for temperature sensor installation:
• A hinged screw fitting (light grey) for immersion sleeve Ø 5.0 and 5.2
• Two brass screw fittings with O-ring and auxiliary tool for direct measurement. Accessories pack with direct measuring
adapter and copper seal. Two information signs for direct measurement.
• Identification plates for immersion sleeves
DEVICE DIMENSIONS
4
A
A
F
F
INSTALLATION INSTRUCTIONS FLOW RATE SENSOR SCREW-IN HEAT METER · CF-ULTRAMAXX
INSTALLATION (FIG. 1)
Turn off the heating circulation pump and close the ball valves. Check the instal-
lation location (return / supply) to make sure this corresponds with the print on
the unit. Remove the distance piece and the seals, and if necessary, clean the
sealing surfaces.
Replacement:
• Turn off the circulation pump
• Close the shut-off valves and release pressure in the pipe
• Break open the seals and unscrew the temperature sensor from the supply
T-piece or from the supply ball valve
• Remove the old heat meter and the seals, and if necessary, clean the sealing
surfaces.
INSTALLATION OF A HEAT METER (FIG. 2)
Install the compact heat meter with new seals in the direction of the flow (follow
the flow direction arrows on the casing).
Caution: the cable must not be cut, squashed or damaged when
removing the unit and during installation!
Caution: ensure tension-free installation - if necessary, ensure that
the pipes are sufficiently anchored in front of and behind the heat
meter.
A
B
130 mm
1"
or
or
110 mm
3 /4"
Fig. 1
A
Fig. 2
F
5