Slip Fitter Models: F1U******S****
All assembly pieces should be packed into
the box for installation. The slip fitter is
designed to be mounted over a 2" [51mm]
pole or 2.38" [60.5mm] max O.D. tenon.
1. Slide the pole base onto application pole
and feed source wire conductor through the
opening of the pole base.
Pole Base
Junction Base
2. Slightly tighten the set screws of the pole
base but do not torque yet.
3. Feed the source wire conductors into the
junction base mounted on the luminaire and
engage the junction base with the mounted
pole base.
9100FLM000900 REV E
Page 4 of 10
ProSite Floodlight for UL 1598/1598A
4. Engage the captive pivot 7/16 hex bolt of
the junction base into the pole base to
secure the luminaire, but do not yet torque as
to still allow the luminaire to tilt for light pattern
aiming.
Cover
5. Tilt and turn the luminaire to desired
position on the application pole to illuminate
the desired area.
6. Once the luminaire is at the desired
position, tighten the pivot hex bolt.
Torque: 11 ft-lbs [14.9 N-m]
7. Tighten the set screws of the pole base to
secure position on the application pole.
Thread locker is recommended.
Torque: 5 ft-lbs [6.8 N-m]
Opening/Closing the Luminaire
This luminaire has 2 lids, a driver enclosure lid
and front access lid. Both lids are retained by
captive bolts and offer a combination head
style for ease of entry. The front access lid is
used for wiring the luminaire for bracket
models while slip fitter models do not use the
front access lid.
Bracket and Mast Arm Models:
Loosen the 4x screws and remove the lid to
gain access to the terminal blocks for wiring.
When wiring is complete, reattach the lid,
and tighten screws back down.
Torque: 30 in-lbs [3.4 N-m]
4x Captive Bolts
NOTE: The lid is secured to the wiring box via
a lanyard; eliminating risk of dropping the lid
upon removal.
NOTE: The lid of the luminaire should be
oriented as shown above. The Dialight logo
should be aligned with the mounting bracket.
Dialight, 1501 Route 34 South, Farmingdale, NJ, USA 07727
Tel: +1 732 919 3119 Fax: +1 732 751 5778
F*U******(E/F/T)****