Chromalox FXTH-21524 Руководство по установке и эксплуатации - Страница 6

Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Электрический нагреватель Chromalox FXTH-21524. Chromalox FXTH-21524 12 страниц. Type fxth flexible tank heater

A. Having circuit breaker and power switch in "off" position, make
sure proper voltage supplied matches voltage of control panel and
elements.
B. Adjust controlling thermostat in terminal housing to a 50°F read-
ing. Increase setting until thermostat switch just "clicks". This
setting is to be used for initial heater checkout.
C. Turn circuit breaker to "on" and note green power light coming
on. Turn on power switch and note first amber light will come on,
and then subsequent amber light(s) as explained in Section.
D. Observe control panel as heater goes through several heating
cycles. A cycle is determined when all amber lights are off. Cycle
interval can vary widely depending on amount of oil in tank.
However, the thermostat has been set to keep the cycle time to a
minimum.
CAUTION: Hazard of electric shock. Any installation involving
electric must be grounded to earth to eliminate shock hazard.
1. A safe maximum temperature limit on control cabinet compo-
nents is 125°F. Choose a mounting location not in direct sunlight
or exposed to any other source of excessive heat. If the panel must
be mounted in direct sun, a sun shield must be employed.
2. Install proper control and power wiring to control center as per
Figure J. Power lines are to be sized for the particular heater load.
Double check to insure proper grounding procedures have been
followed for heaters and control panel.
3. Available inside control panel are connections A and A1 which
provide for an over-temperature alarm; such as, horn, bell, etc., to
be mounted remotely as required. These terminals are rated at
50VA, 120V.
4. Electrical
A. CAUTION: Hazard of severe shock. Make sure circuit
breaker and panel switch are in "off" position.
B. Make knockouts in control cabinet which are desired for final
wiring installation.
C. Connect leads from riser(s) to identified terminals shown on
Figure J.
D. TEMPORARY WIRING TO SIMULATE ACTIVATION OF
CONTROL CIRCUIT.
1. Jumper terminals S to S
2. Connect overtemperature control leads to terminals 5, 6, 7
or 8 as shown on Figure J.
3. Connect green ground wire lead from riser(s) to grounding
lug in control box and from control box to a suitable
ground.
4. Connect power cable of proper voltage to input of control
box.
5. Secure control box door, then place circuit breaker in "on"
position and energize heater with panel switch. Start with
45 second time interval and increase until a definite rise in
temperature on each heater tube can be felt with the bare
hand. NOTE: Adjustable time delay(s) in multi-stage units
have been preset at factory to provide steps for energizing
individual circuits.
6. Observe green light (which indicates "power") when clos-
ing circuit breaker, first amber light with panel switch "on"
and subsequent amber light(s) (if any) at approximately 15
second intervals.
7. Have qualified electrician, using an amprobe, check amper-
age in individual heater leads to insure uniform amperage.
8. Turn circuit breaker to "off" position and remove tempo-
rary jumper from terminals Sand S
ELECTRICAL AND OPERATIONAL CHECKS
INSTALLATION OF REMOTE CONTROL CENTER
.
1
1
E. Turn off circuit breaker and power switch, then re-set thermostat
to desired setting for normal operation. The thermostat contains a
factory adjusted stop which prevents settings above 150°F.
F. If low temperature alarm feature is provided, set this control 10°
to 15°F below the control thermostat setting.
G. Installation of terminal housing lid and gasket (with proper gasket
sealant) completes the check-out procedure.
H. If any difficulties are encountered during the installation and
check-out, call your local Chromalox Representative or
Chromalox Product Service.
Specifications – OCC and WCC Control Center (All Phases)
Max.
No.
Max.
Amps Per
of
Dust and Oil Weatherproof
kW
Volts
Circuit
Circuits Tight Models
6
240
15
1
OCC-15-213
8
240
25
1
OCC-25-213
12
240
30
1
OCC-30-213
15
240
40
1
OCC-40-213
18
240
45
1
OCC-45-213
21
240
55
1
OCC-55-213
24
240
60
1
OCC-60-213
27
240
70
1
OCC-70-213
30
240
75
1
OCC-75-213
12
240
15
2
OCC-15-223
16
240
25
2
OCC-25-223
24
240
30
2
OCC-30-223
30
240
40
2
OCC-40-223
36
240
45
2
OCC-45-223
42
240
55
2
OCC-55-223
48
240
60
2
OCC-60-223
54
240
70
2
OCC-70-223
60
240
75
2
OCC-75-223
18
240
15
3
OCC15-233
30
240
25
3
OCC-25-233
36
240
30
3
OCC-30-233
45
240
40
3
OCC-40-233
6
480
10
1
OCC-10-413
8
480
15
1
OCC-15-413
15
480
20
1
OCC-20-413
18
480
25
1
OCC-25-413
21
480
30
1
OCC-30-413
27
480
35
1
OCC-35-413
30
480
40
1
OCC-40-413
12
480
10
2
OCC-10-423
20
480
15
2
OCC-15-423
30
480
20
2
OCC-20-423
36
480
25
2
OCC-25-423
42
480
30
2
OCC-30-423
54
480
35
2
OCC-35-423
60
480
40
2
OCC-40-423
18
480
10
3
OCC-10-433
36
480
15
3
OCC-15-433
45
480
20
3
OCC-20-433
6
Catalog Number
Dimensions
OCC
WCC
Inches
Models
H
W
D
WCC-15-213
24
20
8
WCC-25-213
24
20
8
WCC-30-213
24
20
8
WCC-40-213
24
20
8
WCC-45-213
30
24
8
WCC-55-213
30
24
8
WCC-60-213
30
24
8
WCC-70-213
30
24
8
WCC-70-213
30
24
8
WCC-15-223
30
24
8
WCC-25-223
30
24
8
WCC-30-223
30
24
8
WCC-40-223
30
24
8
WCC-45-223
42
30
8
WCC-55-223
42
30
8
WCC-60-223
42
30
8
WCC-70-223
42
30
8
WCC-75-223
42
30
8
WCC-15-233
36
30
8
WCC-25-233
36
30
8
WCC-30-233
36
30
8
WCC-40-233
36
30
8
WCC-10-413
24
20
8
WCC-15-413
24
20
8
WCC-20-413
24
20
8
WCC-25-413
24
20
8
WCC-30-413
24
20
8
WCC-30-413
24
20
8
WCC-30-413
24
20
8
WCC-10-423
30
24
8
WCC-15-423
30
24
8
WCC-20-423
30
24
8
WCC-25-423
30
24
8
WCC-30-423
30
24
8
WCC-35-423
30
24
8
WCC-40-423
30
24
8
WCC-10-433
36
30
8
WCC-15-433
36
30
8
WCC-20-433
36
30
8
Approx.
Net Wt.
Lbs.
64
65
65
66
89
91
91
96
96
84
86
86
91
126
128
128
135
135
113
120
125
127
64
64
64
64
64
64
64
84
84
84
89
91
91
96
113
113
113