Dialog Semiconductor DA9231 Руководство пользователя - Страница 8

Просмотреть онлайн или скачать pdf Руководство пользователя для Контроллер Dialog Semiconductor DA9231. Dialog Semiconductor DA9231 18 страниц. Fuel gauge development kit

UM-PM-039
DA9070 / DA9231 Fuel Gauge Development Kit
NDA Confidential
- The boxed jumpers must be installed in designated positions in order to evaluate both DA9070 and
DA9231. If only evaluate DA9070, change J22 jumper to IC_EN=AGND so DA9231 is disabled; If
only evaluate DA9231, remove J14 jumper so DA9070 is disabled.
- Connect the battery to J27. The positive terminal is labeled VBAT_P, adjacent to the red test point
TP26
- Plug in a USB cable into J8 connector. Connect the USB cable to either a traveler adapter or a PC.
The Yellow LED light is ON which means the EVK board is powered. By default, both DA9070 and
DA9231 are OTP programmed to start up automatically as soon as the EVK board is powered.
- If the USB cable is connected to a PC, open the "DA9070 Fuel Gauge EVK" GUI that was installed
on the PC. Start to configure device registers as well as read device status using GUI, as shown in
Figure
4.

Figure 4: GUI for DA9070 Fuel Gauge EVK

User Manual
Revision 2.1
28-Oct-2018
8 of 18
© 2018 Dialog Semiconductor