Miller AlumaPower 450 MPa Руководство пользователя - Страница 6
Просмотреть онлайн или скачать pdf Руководство пользователя для Сварочная система Miller AlumaPower 450 MPa. Miller AlumaPower 450 MPa 49 страниц. Arc welding power source. 400 volt model
EMF DATA SHEET FOR ARC WELDING POWER SOURCE
Product/Apparatus Identification
XMT 450 CC/CV 400V W/AUX POWER (CE)
XMT 450 MPA 400V (CE)
INVISION 450 MPA 400V W/AUX POWER (CE)
ALUMAPOWER 450 MPA 400V W/AUX POWER (CE)
Compliance Information Summary
Applicable regulation
Reference limits
Applicable standards
Intended use
Non-thermal effects need to be considered for workplace assessment
Thermal effects need to be considered for workplace assessment
Data is based on maximum power source capability (valid unless firmware/hardware is changed)
Data is based on worst case setting/program (only valid until setting options/welding programs are changed)
Data is based on multiple settings/programs (only valid until setting options/welding programs are changed)
Occupational exposure is below the Exposure Limit Values (ELVs)
for health effects at the standardized configurations
Occupational exposure is below the Exposure Limit Values (ELVs)
for sensory effects at the standardized configurations
Occupational exposure is below the Action Levels (ALs) at the
standardized configurations
EMF Data for Non-thermal Effects
Exposure Indices (EIs) and distances to welding circuit (for each operation mode, as applicable)
Standardized distance
ELV EI @ standardized distance
Required minimum distance
Distance where all occupational ELV Exposure Indices fall below 0.20 (20%)
Distance where all general public ELV Exposure Indices fall below 1.00 (100%)
Tested by:
Tony Samimi`
275642-A
Product
Directive 2014/35/EU
Directive 2013/35/EU, Recommendation 1999/519/EC
IEC 62822-1:2016, IEC 62822-2:2016
for occupational use
Head
Sensory
Effects
10 cm
0.27
1 cm
Date tested:
Stock Number
907525
907468
907524
907526
for use by laymen
(if NO, specific required minimum distances apply)
n.a
(if applicable and NO, specific measures are needed)
n.a
(if applicable and NO, specific signage is needed)
Health
Trunk
Effects
10 cm
10 cm
0.23
0.36
1 cm
2 cm
2016-03-09
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
Limb (hand)
Limb (thigh)
3 cm
3 cm
0.21
0.47
1 cm
1 cm
24 cm
317 cm