3-1. Serial Number And Rating Label Location

The serial number and rating information for this product is located on the back . Use rating label to determine input power requirements and/or rated
output. For future reference, write serial number in space provided on back cover of this manual.

3-2. Specifications

.
Do not use information in unit specifications table to determine electrical service requirements. See Sections4-5,4-6 and 4-7 for information on
connecting input power.
Ampere
Rated Welding
Range
Model
Output
DC
220 A @
253
29 Volts DC,
30-220 A
35% Duty Cycle
320 A @
343
32.8 Volts DC,
50-320 A
35% Duty Cycle
400 A @
403
36 Volts DC,
60-400 A
35% Duty Cycle
420 A @
443
36.8 Volts DC,
60-420 A
45% Duty Cycle

3-3. Environmental Specifications

A. IP Rating
IP Rating
This equipment is designed for indoor use and is not intended to be used
or stored outside.
B. Information On Electromagnetic Fields (EMF)
!
This equipment shall not be used by the general public as the EMF limits for the general public might be exceeded during welding.
This equipment is built in accordance with EN 60974−1 and is intended to be used only in an occupational environment (where the general public
access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding
circuit may not be a major contributor to the EMF. See the Owner's Manuals for all components of the welding circuit for additional EMF exposure
information.
S
The EMF assessment on this equipment was conducted at 0.5 meter.
S
At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.
C. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low
voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to con-
ducted as well as radiated disturbances.
This equipment does not comply with IEC 61000−3−12. If it is connected to a public low voltage system, it is the responsibility of the installer
or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment can be connected.
IEC/TS 61000-3-4 can be used to guide parties concerned by the installation of arc welding equipment with an input current greater than 16 A
in a low voltage network.
OM-233 381 Page 8
SECTION 3 − SPECIFICATIONS
Max
Open-Circuit
50/60 Hz, Three-Phase
Voltage DC
230 V 380 V 400 V 520 V
59-66 V
36 A
68 V
55 A
66-73 V
73 A
78 V
80 A
IP22S
Amperes Input at
Rated Load Output,
KVA/KW
−−
21 A
−−
14.6/12
32 A
32 A
23 A
22/18
−−
42 A
−−
28/23
47 A
47 A
34 A
32/26
Operating Temperature Range
−10 to 40°C (14 to 104°F)
Dimensions (mm)
Weight
L x W x H
80 kg
980 x 410 x 650
105 kg
980 x 410 x 650
115 kg
980 x 410 x 650
175 kg
1150 x 520 x 730
IP22S 2014 − 06
ce-emf 1 2010-10
ce-emc 2 2014-07