5-9.

Connecting 3-Phase Input Power

4
3
6
Complete Parts List is available at www.MillerWelds.com
3
7
1
Input2 2012−05 Ref. 803 766-C / 803 942-A
= GND/PE Earth Ground
2
L1
5
L2
L3
Installation must meet all National
and Local Codes—have only quali-
fied persons make this installation.
Disconnect and lockout/tagout in-
put power before connecting input
conductors from unit. Follow es-
tablished
procedures
the installation and removal of
lockout/tagout devices.
Always connect green or green/
yellow
conductor
grounding terminal first, and never
to a line terminal.
See rating label on unit and check input volt-
age available at site.
For Three-Phase Operation
1 Input Power Cord
2 Disconnect Device (switch shown in the
OFF position)
3 Green
Or
Green/Yellow
Conductor
4 Disconnect Device Grounding Terminal
5 Input Conductors (L1, L2, And L3)
6 Disconnect Device Line Terminals
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
Connect input conductors L1, L2, and L3 to
disconnect device line terminals.
7 Over-Current Protection
Select type and size of over-current protec-
tion using Electrical Service Guide (fused
disconnect switch shown).
Close and secure door on disconnect device.
Follow established lockout/tagout proce-
dures to put unit in service.