Miller FieldPro Feeder CE Руководство пользователя - Страница 33

Просмотреть онлайн или скачать pdf Руководство пользователя для Сварочная система Miller FieldPro Feeder CE. Miller FieldPro Feeder CE 44 страницы. With weld cable control

Miller FieldPro Feeder CE Руководство пользователя
Trouble
Gun trigger is pressed, gas does not
flow, wire is not energized, wire feeds.
Display on Meter Board PC 22 does not
light.
Segments on Meter Board PC 22 are
missing.
Weld voltage on Meter Board PC 22 is
not accurate.
While not welding − Voltage display al-
ternates between three dashes and
open circuit voltage.
While not welding − Voltage display
alternates between CC and open circuit
voltage.
Weld amperage on Meter Board PC22 is
not accurate.
Software and weld time information on
Meter Board PC 22 is not accurate.
When associated to a WCC control or
WCC compatible power source −
Voltage displayed on feeder does not
match voltage on power source.
Feeder will not associate to a WCC con-
trol or WCC compatible power source.
If a welding arc is not established in 3 seconds after the gun trigger is activated, the unit will feed wire
without energizing the contactor or gas valve. The unit will feed approximately 35 feet (10.7 meters) of
wire, then stop feeding. This is to prevent complete despoolling of the wire, as in the case of a damaged
gun.
Have Factory Authorized Service Agent check Control board PC1.
Replace Meter Board PC 22.
Replace Meter Board PC 22.
Weld voltage on Meter Board PC22 will show weld voltage at the feeder. Due to voltage drops in the weld
cables, weld voltage at the feeder will not match weld voltage at the welding power source. Due to aver-
aging of weld voltage, if weld time is less than 8 seconds the displayed weld voltage at the feeder may
not be accurate.
Check Motor Control PC1 and connections, replace if necessary.
This is normal when unit is connected to a Non−WCC compatible power source (see Section 6-1).
Unit is connected to but not associated to a WCC control or WCC compatible power source
(see Section 5-3).
This is normal when the CC/CV switch is set to CC mode (see Section 6-1).
Amperage displayed at feeder is approximate. Refer to power source for actual amperage
(see Section 5-12)
Check DIP switch settings on Meter Board PC 22 (see Section 5-12).
Check transducer HD1 and connections, and replace if necessary.
Check Motor Control PC1 and connections, replace if necessary.
Check DIP switch settings on Meter Board PC 22 (see Section 5-12).
Check Motor Control PC1 and connections, replace if necessary.
Preset voltages between the feeder and welding power source should be within 0.5 volt of each other.
When associated to a WCC control, verify that the WCC control is configured properly
(see WCC control owner's manual).
While welding the voltage displayed at the feeder is the weld voltage at the feeder. The voltage displayed
at the power source is the weld voltage at the power source. These two voltages will not match due to
voltage drops in the weld cables.
Due to averaging of the weld voltage, if weld time is less than 8 seconds the displayed weld voltage at
the feeder may not be accurate.
Check Motor Control PC1 and connections, replace if necessary.
Follow equipment setup procedure (see Section 5-4).
CC/CV switch must be set to CV to associate to WCC control or WCC compatible power source
(see Section 6-1)
Ensure that the WCC compatible power source Mode Switch is set to V−SENSE FEEDER
(see Section 5-4).
Remedy
OM-267043 Page 27