General
Operating Temperature
IP Code − Degree of protection provided by enclosure
Toppling or tilting
Torch −
The XT30C torch is intended for handheld use only. The torch conforms to IEC 60974-7 when used with the Spectrum 375.
Do not use this torch in combination with any other machines.
Gas Type
Gas Quality
Gas Inlet Flow and Pressure
Gas Filtering
Mild Steel capacities (see Section 5-2 for cutting speeds vs material type and thickness)
Cooling Method
Duty Cycle of Torch
Rating of Electrical Controls (Trigger)
Rating of Electrical Controls (Cup)
Approved Systems
Trigger Protection
Safety Devices
Rated Capacity (edge start)
Sever Cut Capacity (edge start)
Pierce Capacity
*Travel speeds are approximately 80% of maximum.
Dimensions
Plasma Cutter Weight
Requirements for the torch connection
S
Use only compressed air which is free from dirt, oil, and water.
S
Ensure that the connections are properly assigned and tightened.
S
For torch replacement, see Miller torch manual Part No. OM-1593
S
Ensure correct air pressure (flow pressure) and airflow (volume) are set. Insufficient airflow can lead to the torch overheating.
.
If the unit is operated from a 30* ampere, 115 volt circuit or a 15** ampere, 230 volt circuit, a different input power plug must be installed on the
power cord. See Section 4-11 for instructions.
*A 30 ampere branch circuit is recommended for maximum performance. Performance on a 20 ampere branch service may be limited due to the circuit
breaker or line fuse. Reducing unit output amperage will minimize circuit breaker tripping or blowing a line fuse.
**A 15 ampere branch circuit is recommended for maximum performance. Performance on a 10 ampere branch service may be limited due to the circuit
breaker or line fuse. Reducing unit output amperage will minimize circuit breaker tripping or blowing a line fuse.
OM-255 590 Page 12
.
A complete Parts List is available at www.MillerWelds.com
5° to 104° F (−15° to 40° C)
IP − International Protection
2 − No ingress of foreign objects
12.5 mm (0.5 in.)
3 − No harmful ingress spraying
C − AC line circuits protected
against ingress of tool . 2.5 mm
dia x 100 mm long (0.1 in. x 4 in.)
S − Fan stationary during water
Up to 15° incline
Clean, moisture−free,
5.0 SCFM (142 L/min)
Particulates to 5 microns
100% at 30 Amps
30 VDC at .1 Amps
30 VDC at 1 Amp
Spectrum 375 w/XT30C torch
Safety trigger guard
Safety interlock devices shut
down power source
3/8 in. at 15 ipm (457 mm/min)*
13-1/8 in. (333 mm) L
5-1/2 in. (140 mm) W
9 in. (229 mm) H
55 lb (25 kg) including torch
IP23CS
water
test
Air or Nitrogen
oil−free
90 PSI (621 kPa)
Air
5/8 in.
3/16 in.
−−
−−
−−
−−
−−
−−
−−
−−
−−
−−
−−
−−
−−
−−
−−
−−
−−
−−
−−
−−
120 PSI (827 kPa)
Min
Max
−−
−−
−−
−−
−−
−−
− −
− −
− −
− −
−−
−−
−−
−−
−−
−−
− −
− −
− −
− −