Miller ArcReach SuitCase 12 Руководство пользователя - Страница 16

Просмотреть онлайн или скачать pdf Руководство пользователя для Сварочные принадлежности Miller ArcReach SuitCase 12. Miller ArcReach SuitCase 12 48 страниц.

Miller ArcReach SuitCase 12 Руководство пользователя

5-1. Equipment Connection Diagram

1

5-2. ArcReach Applications

.
To take advantage of the ArcReach features, the ArcReach wire feeder must be used with an ArcReach Control, or an ArcReach compatible weld-
ing power source. The ArcReach wire feeder may also be used as a standard feeder on any Non-ArcReach power source.
.
This wire feeder has the ability to associate with an ArcReach compatible welding power source at power up, or when wire feeder is triggered.
For either method, the welding power source must be in an Output On mode. See instructions in the welding power source Owner's Manual.
.
This wire feeder has the Cable Length Compensation feature, see Section 6-2 for details.
5-3. Associating Wire Feeder To ArcReach Compatible Power Source Or
ArcReach Control
Associating wire feeder to an ArcReach compatible welding power source at power up
.
The welding power source must be in an Output On mode. See instructions in the welding power source Owner's Manual.
.
On wire feeder, set CC/CV switch to CV mode. The feeder will not associate with another piece of equipment if the feeder is set to CC mode.
.
If associating to a Power Source with the Cable Length Compensation feature, see Section 6-2 for details.
1
Turn on the welding power source and wire feeder.
2
Decimal points on feeder voltmeter will blink.
3
When decimal points stop blinking and a voltage is displayed, the feeder and power source are associated. The association process may take
several seconds to complete.
4
Dependent on the capabilities of the ArcReach power source, the feeder may set the mode switch to the correct wire mode. The wire mode is
determined by the polarity of the connections to the feeder.
5
Use voltage control on feeder to adjust preset weld voltage.
6
The voltmeter on the feeder will display preset weld voltage while idle or weld voltage while welding.
OM-278792 Page 12
SECTION 5 − INSTALLATION
2
3
4
6
5
!
Turn Off wire feeder and
welding power source. Stop
engine on welding
generator.
!
Do not move or operate
equipment where it could
tip.
!
Use only with CC/CV DC
power sources.
1
Welding Power Source
10
2
Gas Hose
3
Weld Cable To Feeder
4
Work Cable To Workpiece
Weld cable and work cable connec-
tions to power source (DCEN/
DCEP) are dependant on wire type.
.
Since feeder is not polarity sen-
sitive, there is no need for an
electrode polarity switch.
5
Workpiece
9
6
Voltage Sensing Clamp
Connect voltage sensing clamp to
8
workpiece.
7
Gun
8
Gun Trigger Receptacle
9
Wire Feeder
10 Gas Cylinder
Use of shielding gas is dependant
on wire type.
.
7
Shielding gas pressure not to
exceed 100 psi (689 kPa).
Ref. 278805-A