Miller RFCS-14HD Руководство пользователя - Страница 6
Просмотреть онлайн или скачать pdf Руководство пользователя для Сварочные принадлежности Miller RFCS-14HD. Miller RFCS-14HD 16 страниц. Foot controls
Также для Miller RFCS-14HD: Руководство пользователя (12 страниц), Руководство пользователя (16 страниц)
1-2. Typical Connection
1
1-3. Remote Amperage Control For Welding Power Source Without
Remote Control Switch
Select Weld Process
OM-844 Page 2
2
Select Range And Polarity
!
1
2
Insert plug into matching 14-sock-
et, 5-socket, or 6-socket recep-
tacle, as applicable, on welding
power source. Tighten collar.
Approximately
Select Maximum
Amperage Percentage.
50% = Approx. 33 A DC
Turn Off welding power
source before connecting
foot control.
Foot Control
Remote 14, Remote 5, Or
Remote 6 Receptacle
Ref. 801736
Off
0 A DC
On
33 A DC
Combination Front Panel
And
Remote Control
Press pedal lightly to turn
weld output and gas flow
on. Press pedal further to
increase weld
output.
Release pedal to turn off
weld output and gas flow.
Ref. 155790-H