Wellness Steam Shower Cabins (S6)
Steam Generator Cleaning
Remove the cover of cleaning liquid inlet and input
around 1L of citric acid or acetic acid. Then start steam
function to fill steam generator with water. Stop steam
function before steam coming out (acid steam has
causticity to plated parts. If a lot of acid steam come out,
the plated parts become cloudiness after some time.)
Do not shut off the control system and keep it on. The
scale in the steam generator dissolves in acid liquid and
the system drains the dirty water out automatically after
60 minutes. Clean the steam generator every 3 months.
Trouble Shooting for Steam Cabin
TROUBLE
CAUSE
1.Communication line is short
circuit or open circuit.
Touch panel
does not work.
2.The control system is wrong.
1.The water supply is shut off.
2.No water supply in this area.
No Steam
3.The water inlet valve cannot
be turned on.
4.The water level sensor is wrong.
013
SOLUTION
Check connection between
control panel and power box.
Change control panel or
power box.
Turn on the water supply valve.
Use the product when water
supply is normal.
Check water inlet valve and
output signal from it.
Clean scale on water level
sensor or replace it.
Trouble Shooting for Steam Cabin
TROUBLE
CAUSE
Thermal switch in the heater
is wrong.
No Steam
The heater is wrong.
The set temperature is lower
than room temperature.
The water inlet electro-
magnetic valve is wrong.
Steam generator
keeps adding
water.
Water level sensor could not
detect signal.
There is creepage from heater.
Power supply is
off when on/off
button is pushed.
There is creepage from
thermal switch inside heater.
Water leaks
The seal is damaged.
from valve.
Water supply has impurities
Water flow
and jammed the filter net.
volume is low.
SOLUTION
Change thermal switch installed
inside the heater.
Change the heater.
Reset temperature.
Replace water inlet valve
Clean scale on water level
sensor or replace it.
Replace heater.
Replace thermal switch.
Change the seal.
Get filter net cleaned.