MAINTENANCE INSTRUCTIONS (Continued)
Resetting the High Limit Switch
For various reasons the high limit safety shut off switch will occasionally shut the water heater down
This shut down will occur when water temperatures exceed 190°F. Power is automatically turned off to
the heating element. The shut off device may also activate as a result of a power outage or an electrical
storm.
Note:
Do not attempt to reset the high limit switch without first allowing the water heater to cool down
the high temperature water inside the heater.
Warning:
Do not tamper with the reset button to override overheating shut down.
1. Turn off the power switch and unplug the water heater from the electric outlet.
2. Drain and remove the water heater. (see page 11)
3. Remove six screws retaining the bottom panel of the water heater and remove the panel.
Locate the high limit reset button.
4. Depress the small red button in the center of the junction box, replace the bottom panel and
place the water heater back into service.
Note:
A lower temperature setting saves energy and reduces the risk of scalding.
Caution:
Call a technician if the high limit needs to be reset frequently.
High Limit Reset Button
3100-010-001
10/17 REV 1
Heating Element
TOLL FREE 800-447-4962 • LOCAL 626-937-4270 • FAX 626-937-4279
Page 13 of 16