TABLE 2 – Flow Switch Activation
Flow Switch Activation
Low Activation (L)
Standard Activation (S)
High Activation (H)
THE MANUFACTURER OF THIS WATER HEATER WILL NOT BE LIABLE FOR ANY DAMAGES CAUSED BY THE FAILURE
TO FOLLOW THESE INSTALLATION AND OPERATION INSTRUCTIONS.
CAUTION:

BEFORE BEGINNING THE INSTALLATION:

1. Turn off circuit breaker to avoid dangerous electrical shocks.

2. Turn off water supply.

INITIAL INSTALLATION:

1. Before installation, compare electrical requirements needed for the model of heater selected in Table 1.
2. Remove heater cover. Mount unit horizontally flush against the wall (See Fig. 1). Water connections will
be either on right hand side or left hand side only. If water connections are at top or bottom, heater is
not in correct position. Mount with four screws through the mounting holes located on the base plate
housing using molly anchors or fasteners. CAUTION: Heating elements may burn out if unit is not
mounted with heater modules horizontally.
3. Insure placement of heater allows 5" clearance for screwdriver access to remaining 3 sides of heater to
allow cover removal, and future servicing if needed. (See Fig. 1).
4. Attach electrical conduit and fittings to the 1" electrical access hole on either top or bottom of base plate.
Access hole can be enlarged to next trade size if needed. Do not attaching wiring yet.
5. Connect plumbing. Use ¾ inch tapered national pipe thread at cold-water inlet and hot water outlet (See
Fig. 1). Use unions and valve(s) for ease of installation and possible servicing. Use Teflon tape or pipe
sealing compound. Do not apply heat to these fittings, as damage to the heater modules will occur and
void warranty. Rough out plumbing with heater in place, then remove heater during soldering of
connections.
6. Run water through the unit to expel all air bubbles. Cycle downstream faucet 10x to assist removing air
bubbles. This will also pressurize unit. Check for leaks at all fitting joints and also inside heater.
7. If no leaks, proceed to Electrical Installation Section and Figure 2.
3 Module Heaters
0.35 GPM
1.20 GPM
2.80 GPM
2 |
P a g e