4.4 – PJ microprocessor instructions
4.4.1 Definitions
Set Point – The lowest temperature in ºC inside the counter.
Differential – Interval of temperature in ºC for the working of the counter.
4.4.2 Change of the SET POINT (inside minimum temperature of the cabinet)
1- Press the
key for 1 second to display the value of the SET POINT ;
2 – After some time the preset value blinks;
3 – Use the
key or
4 –Press
for 5 seconds to confirm the new value.
4.4.3 Change of the DIFFERENTIAL
1- Press
for 5 seconds, it shows PS;
2 – Press the key or
or
3 – Press the key
to display the value of the parameter;
4 – Press the key
or
5 – Press the key
to confirm temporarily the new value and display the parameters code;
6 – To memorise the new value press the
4.4.4 Configuration for HACCP control on the refrigerated equipment with PJ controller + module
St - set point – Working temperature
rd – Temperature differential
AH – Highest temperature level allowed without alarm
AL – Lowest temperature level without alarm
Ad – Delay of temperature alarm
MNS00027.02
TEC
INSTRUCTIONS MANUAL
to increase or decrease the value;
till the parameter rd;
to change the value;
key for 5 seconds.
St - set point
Rd - Differential
tu – day of the week
th – hour
t' – minutes
tr – period of delay of HACCP alarm
to – global reset of the HA and HF alarms
N.º
MNS00027.02
12/45