Aquasana EQ-600 Руководство пользователя - Страница 9
Просмотреть онлайн или скачать pdf Руководство пользователя для Системы фильтрации воды Aquasana EQ-600. Aquasana EQ-600 16 страниц. Whole house water filter
Также для Aquasana EQ-600: Руководство по установке (5 страниц), Руководство пользователя (16 страниц)
Performance Data Sheet for the EQ-300 Aquasana Whole House Rhino
Models
Replacement
EQ-300R
EQ-300 / EQ-301
Manufactured by: Aquasana, Inc. 6310 Midway Road · Haltom City, Texas 76117 · 866-662-6885
Testing Performed under NSF/ANSI Standards 42 for reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit
for water leaving the system, as specified in NSF/ANSI 42.
NSF/ANSI 42
Chlorine Reduction, Free Available
Data Summary Table
Accumulated
Volume (gal)
Sample
Point
Effluent 1
Startup
150
10%
30,000
20%
60,000
30%
90,000
40%
120,000
50%
150,000
60%
180,000
70%
210,000
80%
240,000
90%
270,000
100%
300,000
System Tested and Certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine
Taste and Odor.
For use with municipally treated water only. Do not use with water that is microbiologically unsafe or of
unknown water quality without adequate disinfection before or after the system.
• All contaminants reduced by this filter are listed.
• Not all contaminants listed may be present in your water.
• Does not remove all contaminants that may be present in tap water.
Filter is only to be used with cold water.
Filter usage must comply with all state and local laws.
Testing was performed under standard laboratory
conditions, actual performance may vary.
Max Operating pressure
Rated capacity
100 psi
300,000 gallons
Influent Challenge
Pressure drop
Chlorine
2 mg/L ±10%
10.5 psi
Dynamic Pressure
Chlorine, Free Available
(psi)
(mg/L)
Influent
Influent
62
1.9
62
2.1
62
2.0
62
1.9
62
2.1
62
2.0
61
1.8
62
2.1
61
2.0
60
2.0
61
2.1
Water Filter System
®
Operating temp. range
40-90º F
Minimum
Overall %
reduction
reduction
≥50%
>97.1 %
Flow Rate (gpm)
Effluent 1
Effluent 1
ND (0.05)
7.2
0.07
7.1
ND (0.05)
7.1
ND (0.05)
7.1
ND (0.05)
7.2
ND (0.05)
7.1
ND (0.05)
7.0
ND (0.05)
7.1
ND (0.05)
7.1
ND (0.05)
7.1
0.11
7.0
Systems certified for cyst reduction may be
used on disinfected waters that may contain
filterable cysts.
See owner's manual for general installation
conditions and needs plus manufacturer's
limited warranty.
Rated flow
7.0 gpm
Results
Pass