6
INSTALLATION STEPS
2
3
Filtration System Add-Ons Preparation
If you've added any additional components to your filtration system,
stop now and read the separate, individual manuals for those systems
in their entirety.
4
When installing on metallic plumbing, ensure you take the following
precautions. Securely install two (2) grounding clamps and a #4 copper
wire (not included) across the location where the system will be installed.
Tightly clamp at both ends, as shown in the illustration.
Ground
Clamp
ELECTRICAL SHOCK HAZARD
Prior to installation on metallic plumbing, securely install two grounding clamps and a #4 copper wire
per installation instructions. Failure to follow these instructions can result in death or electric shock.
Cut Pipes
5
1. Using a pipe cutter, cut into the main water supply line along the
marked sections from step 2 to install the shut-off valve and clean ends
of pipe. Ensure there are no burrs, sharp edges, or deep scratches. Cut
tubing as straight as possible with a utility knife, or an appropriate pipe
cutter for copper tubing or PVC.
2. If you are installing a bypass loop, now is the time to plan accordingly
and install (recommended, not included).
3. Loosely fit shut-off valve to calculate proper spacing of components.
NOTE: DO NOT cut more pipe than
necessary. You can cut more pipe
later if needed.
COPPER PIPES ONLY (proceed to Step 5 for PVC Pipes)
Ground Wire
WARNING
Ground
Clamp