Installing Your Smoke Detectors
Read"Locations to Install Your Smoke Detectors" and "Locations not to Install
Your Smoke Detectors" section in the manual first, and then decide where to
install the detector.
Please follow these steps to install your smoke detector:
1
At the place where you are going to install the detector, draw a horizontal line
six inches long.
2
Remove the mounting bracket from your unit by rotating it counterclockwise.
3
Place the bracket so that the two longest hole slots are aligned on the line. In
each of keyhole slots, draw a mark to locate a mounting plug and screw.
4
Remove the bracket.
5
Using a 3/16-inch (5mm) drill bit, drills two holes at the marks and insert
plastic wall plugs. Put the detector away from getting plaster dust on it when
you drill holes for mounting.
6
Using the two screws and plastic wall plugs (all supplied), attach the bracket to
the wall.
7
Line up the slot of the bracket and the detector. Push the clockwise to fix it
into place. Pull outward on the detector to make sure it is securely attached to
the mounting bracket.
BRACKET
DETECTOR
SCREWS
SCREWS
8
The steps to open the battery cover and to install the battery are listed as
follows:
To power smoke detector requires a battery.
(1)
(2)
Match terminals on the end(s) of the battery with opposite terminal
connections on the detector. Be sure to insert the zinc-manganese dry
battery in the position shown on the detector.
(3)
When terminals are properly matched, push battery firmly in until it snaps
and cannot be shaken loose.
BATTERY
CAUTION:
This smoke detector comes with cover latches that will prevent the
smoke detector cover from closing if battery is not installed. This tells you that
the smoke detector will not work until a new battery is properly installed. The
battery is purposely positioned WRONGLY in the factory to keep it fresh
until installation. It must be re-positioned correctly to provide DC power.
NOTE:
When the detector battery first makes contact with the detector, the
alarm horn may sound for one second. This is normal and indicates that the
battery is positioned properly. Close cover, then press the test button, holding
it down for about 5 seconds until the horn sounds. The horn should sound a
loud, pulsating alarm. This means the unit is working properly.
LOUDSPEAKER
RED LED
TESTING BUTTON
Connect with Alarm Control Panel
SMK-500 can not only work as a single station, but also can work with alarm
control panel to form an alarm system when wireless module is added to the
smoke detector.
1) Make sure the control panel is in learning state.
2) Press the testing button on the smoke detector for 3 seconds, two beeps
are heard. Simultaneously, one beep is heard from the control panel. The
detector has been connected successfully with the control panel.
Testing:
Press the testing button on the smoke detector for 3 seconds, the control
panel will alarm immediately.
Red LED Indicator
The red LED, as the ALARM indicator, is featured with the detector. It can be
seen through the test button on the cover of the detector. When red LED
flashes once 32 seconds, it indicates the detector under normal operation.
When smoke detector senses smoke and simultaneously sounds an audible
alarm, the red LED will flash very frequently, once 0.67 seconds.
Testing Your Smoke Detector
Test the detector weekly by pushing firmly on the test button with your finger
until the horn sounds. Testing method may take up to 5 seconds to sound the
alarm horn. These are only ways to be sure that detector is working correctly.
If the detector fails to test properly, have it repaired or replaced immediately.
WARNING:
Never use an open flame to test your detector. You may set fire to
damage the detector, as well as your home. The built-in test switch accurately
tests all detector functions, as required by Underwriters' Laboratories. They
are the only correct ways to test the unit.
WARNING:
When you are not testing the unit and the alarm horn sounds a
loud continuous sound, this means the detector has sensed smoke or
combustion particles in the air. Be sure that the alarm horn is a warning of a
possible serious situation, which requires your immediate attention.
The alarm could be caused by a nuisance situation. Cooking smoke or a dusty
furnace, sometimes called "friendly fires" can cause the alarm to sound. If this
happens, open a window or fan the air to remove the smoke or dust. The
alarm will turn off as soon as the air is completely clear.
NOTE:
Do not disconnect the battery from the detector. This will remove your
protection from fires.
Using The Silence Feature
The silence feature can temporarily quiet an unwanted alarm for up to 8
minutes. To use the feature, press the"TEST" button .When remain in silence,
the LED will flash once every 8 seconds (for up to 8 minutes) to remind you
the alarm has been stopped. The flashing LED will stop when the unit returns
to normal operation.
WARNING: The silence feature does not disable the unit. It is temporarily less
sensitive to smoke. For your safety, if smoke around the unit is dense enough
to suggest a potentially dangerous situation, it will stay in alarm, or may re-
alarm quickly. If you do not know the source of the smoke, do not assume it is
an unwanted alarm. Not responding to an alarm can result in property loss,
injury or death.
NOTE: Do not disconnect the battery from the detector. This will remove your
protection from fires.
˙
If a beep or chirp virtually simultaneously with an LED flash once a minute,
this means the detector 's battery is weak. Replace new battery immediately.
If a beep or chirp occurring halfway an LED flash once a minute, this signal
means that the detector is faulting, it is must repaired or replaced
immediately.
Taking Care of Your Smoke Detector
To keep your detector in good working condition, you must test the detector
weekly, as referring to section "TESTING YOUR SMOKE DETECTOR".
Replace the detector battery when the low battery "beep" signal sounds once
a minute. The low battery "beep" should last at least 30 days.
NOTE:
For replacement battery, use Gold Peak 1604P , 1604S, 1604G, 1604A;
Eveready522, 216; Duracel Mn1604; PremisafeG6F22; UltralifeU9VL-J; EVE
CR9V.
WARNING:
Do not use any other kind of battery. This detector may not
operate properly with other kind of battery.
Open the cover and vacuum the dust off the detector 's sensing chamber at
least once a year. This can be done when you open the detector to change
the battery. Remove battery before cleaning. To clean detector, use soft brush
attachment to your vacuum. Carefully remove any dust on detector
components, especially on the openings of the sensing chamber. Replace
battery after cleaning. Test detector to make sure battery works correctly.
Check to make sure there is no obstruction inside the test button. If there is
any dust in the test button, insert a toothpick from the back to the front.
NOTE:
If nuisance alarms keep coming from the detector, you should check
whether the detector 's location is adequate. Refer to section "WHERE TO
INSTALL SMOKE DETECTORS." Move your detector if it is not located properly.
Clean detector as described above.
Clean detector cover when it gets dirty. First open the cover and remove
battery. Hand-wash cover with cloth dampened with clean water. Dry it with
lint-free cloth. Do not get any water on the detector components. Replace the
battery, and close cover. Test detector to make sure that battery works
correctly.
Technical Specifications
Power Supply:
DC 9V 6F22 batter y x 1
Standby Current:
≤
5uA
Alarm Current:
≤15mA
LED Frequency in Working State:
Once ever y 32 sec.
LED Frequency in Alarming State:
Once ever y 0.62 sec.
Low Battery State:
Beep once with a LED flash per 60s (last for 30 days)
Operation Condition
Temperature: -10°C ~ +55°C
Relative humidity: ≤95%(no condensing)
Monitoring Area:
20m
2
Alarm Decibel:
85dB/3m
Radio Frequency:
315MHz, 433.92MHz or 868MHz
Transmitting Distance:
≤
80m in open area(SMK-500)
Housing Material:
ABS plastic
Dimensions (L x W x H) :
102x102x31mm