AquaStar 125B NGS Руководство по установке и эксплуатации - Страница 16

Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Водонагреватель AquaStar 125B NGS. AquaStar 125B NGS 16 страниц. Automatic instantaneous type water heaters for use with natural and liquefied petroleum gas

Nominal Iron Pipe Size*
MAXIMUM LENGTH
Semi-rigid Tubing
MAXIMUM LENGTH
* Flex tubing greatly reduces capacity and, therefore, is not recommended.
Minimum Diameter
* NOTE: Vent size must not be restricted. Installation must comply with national fuel gas code venting requirements
for a 117,000 Btu Category I appliance and any applicable local codes.
** NOTE: Minimum vent height must be 6 feet, provided there are no elbows. Termination of the vent must be 2
feet above any obstruction within a 10 foot radius of vent pipe. Consult your gas utility or National Fuel Gas Code
if vent will have elbows or share venting with another appliance. The vent connector should have as much vertical
For installation on well systems, insure that your water pressure is between 30 - 50 psi.
Replacement Parts available from North American Distributor
CONTROLLED ENERGY CORP.
340 Mad River Park
Vermont 05673 (U.S.A.)
Phone 800-642-3111
Fax (802) 496-6924
WWW.CECHOT.COM
GAS LINE SIZE
1/2"
10'
Liquid Propane
1/2"
NOT
RECOMMENDED
Minimum Vent Size* and Height
5 inches
rise as possible (minimum 12") before any horizontal run.

Water Pressure

INSTALLATION CHECKLIST

Natural Gas

3/4"
40'
5/8"
20'
VULCANO Termodomésticos S.A.
1"
150'
3/4"
60'
Minimum Height**
6 feet**
Estrada de Cacia
3800 Cacia - PORTUGAL
7/8"
150'
Recycled paper