Diamond H2O Reliant DRS4-EM-66 Руководство - Страница 19

Просмотреть онлайн или скачать pdf Руководство для Диспенсер для воды Diamond H2O Reliant DRS4-EM-66. Diamond H2O Reliant DRS4-EM-66 19 страниц. Reliant drs4 series single tank water softener

Error Codes Cont...
Problem
E3, Err-1003, Err-103 =
Control valve motor ran too
long and was unable to find
the next cycle position and
stalled
E4, Err-1004, Err-104 =
Control valve motor ran too
long and timed out trying to
reach home position
Possible Cause
Motor failure during a
regeneration
Foreign material built up
on piston and stack
assemblies creating
friction and drag enough
to time out motor
Drive bracket not snapped
in properly that reduction
gears and drive gear do
not interface
Drive bracket not snapped
in properly that reduction
gears and drive gear do
not interface
Solution
Check motor connections. Press NEXT and
REGEN buttons for 3 seconds to resynchronize
software with piston position or disconnect
power supply from PC board for 5 seconds and
then reconnect.
Replace piston and seal/stack assemblies. Press
NEXT and REGEN buttons for 3 seconds to
resynchronize software with piston position or
disconnect power supply from PC board for 5
seconds and then reconnect.
Snap drive bracket in properly. Press NEXT and
REGEN buttons for 3 seconds to resynchronize
software with piston position or disconnect
power supply from PC board for 5 seconds and
then reconnect.
Snap drive bracket in properly. Press NEXT and
REGEN buttons for 3 seconds to resynchronize
software with piston position or disconnect
power supply from PC board for 5 seconds and
then reconnect.
pg. 18