M
OUNTING
Introduction
The Baseline Switch is supplied with two mounting brackets and four
screws. These are used for rack mounting and wall mounting the
unit. When mounting the unit, you should take note of the
"Positioning the Baseline Switch"
guidelines given in
Wall Mounting the Units
CAUTION: Disconnect all cables from the unit(s) before
continuing. Remove the self-adhesive pads from the
underside of the unit(s), if already fitted.
Fitting the brackets to wall mount one unit:
1
Place the unit the right way up on a hard, flat surface with the
front facing towards you.
2
Locate a mounting bracket over the mounting holes on one
side of the unit, as shown in Figure 1 below.
3
Insert the two screws and fully tighten with a screwdriver.
Repeat the last two steps for the other side of the unit.
Fitting the brackets to wall mount two units:
1
Stack the units the right way up on a hard, flat surface with
the front facing towards you.
2
Locate two mounting brackets over the mounting holes on
one side of the units, as shown in Figure 2 below.
3
Insert the three screws and fully tighten with a screwdriver.
Repeat the last two steps for the other side of the units.
Figure 1
Wall Mounting One
Unit
K
I
IT
NSTRUCTIONS
overleaf.
Figure 2
Wall Mounting Two
Units
6
To wall mount the unit(s):
Ensure that the wall you are going to use is smooth, flat, dry and
sturdy. Attach a piece of plywood, about 30cm x 50cm x 1.5cm
(12in. x 20in. x 0.5in.) in size, securely to the wall if necessary, and
mount the unit(s) as follows:
1
Position the unit(s) against the wall (or plywood) ensuring that
the ventilation holes face sideways. Mark on the wall the
position of the screws holes for both wall brackets. Drill the
four holes.
2
Using suitable fixings and screws (not provided), attach the
unit(s) securely to the wall (or plywood).
Reconnect all cables.
Rack Mounting the Units
The Baseline Switch is 1U high and will fit a standard 19-inch rack.
CAUTION: Disconnect all cables from the unit before
continuing. Remove the self-adhesive pads from the
underside of unit, if already fitted.
1
Place the unit the right way up on a hard, flat surface with the
front facing towards you.
2
Locate a mounting bracket over the mounting holes on one
side of the unit, as shown in Figure 3 below.
3
Insert the two screws and fully tighten with a suitable
screwdriver.
4
Repeat the two previous steps for the other side of the unit.
5
Insert the unit into the 19-inch rack and secure with suitable
screws (not provided).
Reconnect all cables.
Figure 3
Rack
Mounting