AQUATECH CAN165-300 Руководство по эксплуатации - Страница 7

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Диспенсер для воды AQUATECH CAN165-300. AQUATECH CAN165-300 16 страниц. 165 series

General System Installation

Installing the Bypass valve
1. Locate the softener tank and brine tank close to a drain where the system will be installed. The surface should be clean and
level.
2. Perform all plumbing according to local plumbing codes.
 Use a ½" minimum pipe or tubing size for the drain line
 Use a ¾" pipe or tubing for backwash flow rates that exceed 7 gpm or length that exceeds 20ft (6 m)
 ON COPPER PLUMBING SYSTEMS BE SURE TO INSTALL A GROUNDING WIRE BETWEEN THE INLET AND OUTLET PIPING TO
MAINTAIN GROUNDING.
Water Pressure
Minimum 25 PSI
Electrical Supply
Uninterrupted 115V AC
Existing Plumbing
Free of any deposits or build-ups inside pipes.
Softener Location
Locate close to drain and connect according to
plumbing codes
Bypass Valves
Always provide for bypass valve if unit is not
equipped with one.
Plumbing
Softener and or other water treatment
equipment should be installed to local
plumbing codes
CAUTION
Figure 6. Piping Diagram
Figure 7. Bypass Assembly View
Do not exceed 120 psi water pressure.
Do not exceed 110°F water temperature.
Do not subject unit to freezing
conditions.
7