AQUATECH CAN165BM-100 Руководство - Страница 9

Просмотреть онлайн или скачать pdf Руководство для Системы фильтрации воды AQUATECH CAN165BM-100. AQUATECH CAN165BM-100 19 страниц. 165 series birm filter

HYDROGEN SULFIDE (H
S)
2
Hydrogen sulphide (often referred to as "sulphur"), is easily detectable by its objectionable "rotten egg" odour. Sulphur corrodes
iron, brass, copper and silver. A chemical free iron filter is not recommended when hydrogen sulphide is present. Please contact
your Independent Water Tech representative for further recommendations.
LOCATE WATER CONDITIONING EQUIPMENT CORRECTLY: (see drawings page 9)
Select the location of your filter tank with care. Various conditions which contribute to proper location are as follows:
1. Locate as close as possible to water supply source.
2. Locate as close as possible to a floor or laundry tub drain.
3. Locate in correct relationship to other water conditioning equipment.
4. Filters and softeners should be located in the supply line before the water heater. Temperatures above 120°F damage
filters and softeners, and will void the factory warranty.
5. Do not install a filter or softener in a location where freezing temperatures occur. Freezing may cause permanent damage
to this type of equipment, and will void the factory warranty.
6. Allow sufficient space around the unit for easy servicing.
THE IMPORTANCE OF YOUR PRESSURE TANK
The pressure tank found on private well systems becomes an integral part of the filter system by providing necessary mixing and
"contact time" to the "Air-Charged" water. While the iron filter will perform better on a standard water to air pressure tank, it will
perform satisfactorily on a captive air (bladder) type pressure tank. The bladder type requires more careful adjustment of the Air-
Charger and the careful location of the air relief valve. If cycle time on pumping system is less than 30 seconds and under severe
operating conditions (low pH, high iron, manganese, and small concentrations of sulphur), a standard air-to-water type pressure
tank with an air-relief valve must be used (if a bladder type tank is already in place — do not remove it — install the air-to-water
pressure tank between the Air-Charger and the bladder type tank).
NOTE:
If your pressure tank (or any part of the water system) is not functioning properly, corrective action must be taken
before installation of your iron filter.
9