Table 9
Fabric OS 4.4.0e closed issues summary
Closed defect
Issue: Zone daemon (zoned)
occasionally panics during zone
changes.
Symptom: Switch panics with zoned
when performing zoning changes
and leaves behind a stack backtrace
with cfgBufGetEnableSig as
the top frame.
Issue: With a 3rd party switch, when
receiving an empty data record, the
zone daemon (zoned) panics in
interopmode.
Symptom: zoned assert in
merge/zn_merge_dbg.c:452
Issue: Class3 frames could be
dropped in session based zoning
when a different port in the same
zone goes off/on line.
Symptom: Customer's 3rd party box
reports frame drop error.
Issue: swFabricWatchTrap has
#SUMMARY and #ARGUMENTS out
of sync with OBJECTS order <H271>
Solution: The new varbinding
command
swEventSeverityLevel was
added in the varbind list but the
argument list was not changed
properly. Correct SNMP MIB to
match the summary and argument
list.
46
Closed issues from Fabric OS 4.4.0e
Status
Fixed.
Fixed.
Fixed.
Fixed