Panasonic PT-FX400EA Руководство по эксплуатации - Страница 42
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Проектор Panasonic PT-FX400EA. Panasonic PT-FX400EA 46 страниц. Pt-fw430 series lcd projector
Также для Panasonic PT-FX400EA: Технические характеристики (6 страниц)
Control commands via LAN
When WEB Control administrator rights password is set (Protect mode)
Connection method
1)
Obtain the IP address and port number (Initial set value = 1024) of the projector and
make a request for connection to the projector.
Acquire the IP address from the menu screen of the projector, and the port number from the WEB control
page.
IP address :
Obtain from MAIN MENU → [NETWORK] → [STATUS]
Port No. :
Acquire from the WEB control "advanced setting" → "command port setting" page
2)
There is a response from the projector.
Response data
Data section
"NTCONTROL"
(ASCII string)
9 bytes
Mode : 1 = Protect mode
3)
Generate a 32-byte hash value from the following data using MD5 algorithm.
"xxxxxx:yyyyy:zzzzzzzz"
xxxxxx :
Administrator rights user name for WEB CONTROL (Default user name is "admin1")
yyyyy :
Password of above administrator rights user (Default password is "panasonic")
zzzzzzzz :
8-byte random number obtained in Step 2
Command transmission method
Transmit using the following command format.
Transmitted data
Hash value
(See above
<Connection method>)
32 bytes
Receive data
'0'
0x30
1 byte
Error response
"ERR1"
"ERR2"
"ERR3"
"ERR4"
"ERR5"
"ERRA"
42
Blank
Mode
' '
'1'
0x20
0x31
1 byte
1 byte
Header
'0'
0x30
1 byte
Header
'0'
0x30
1 byte
Error message
Undefined control command
Out of parameter range
Busy state or no-acceptable period
Timeout or no-acceptable period
Wrong data length
Password mismatch
4 bytes
Blank
' '
(ASCII code hexadecimal
0x20
1 byte
Data section
'0'
Control command
0x30
(ASCII string)
1 byte
Undefined length
Data section
Control command
(ASCII string)
Undefined length
Random number
section
"zzzzzzzz"
number)
8 bytes
Termination symbol
(CR)
0x0d
1 byte
Termination symbol
(CR)
0x0d
1 byte
Termination symbol
(CR)
0x0d
1 byte
Termination
symbol
(CR)
0x0d
1 byte