Conv. factor
1.000
Zero press cal
0.460
Ground speed cal
10427
CSS 110 Automatic Sprayer Controller
11001-1679-201606

CONVERSION FACTOR

Relates to product density.
– Press the OK button once. The decimal point flashes to allow
– Press the OK button to confirm and program to desired setting.
In case of emulsion, set value to 1.000.

ZERO PRESSURE CALIBRATION

This constant is automatically calculated by the CSS 110.
V
– Press the OK button once. The digits flash momentarily until the
IMPORTANT: A Zero Pressure Calibration is required anytime the

GROUND SPEED CALIBRATION

Calibration of ground speed is required and can be performed in two
methods:
Entering a Known Ground Speed Constant:
1. Press the OK button and enter the known constant.
Performing a Ground Speed Calibration to find the Constant:
If a ground speed constant is not known, perform a calibration as follows:
1. Measure a 100m infield course; ideally on level ground.
2. Mark the start and finish points.
3. Move the tractor several meters before the start position of the 100m
course.
4. Begin driving with a constant speed of 4 km/h.
5. When even with the starting point of the 100m course, press the OK
button.
– The display read should go to 0, then begin counting up while the
6. Continue to drive the course at a constant speed.
7. When reaching the finish marker, please the OK button.
8. The ground speed calibration will display.
9. Record the number as a first run; repeat the calibration steps two more
times.
10. After the third run, average the test results and enter this number as
the constant.
moving it using the + and - buttons.
There should be NO pressure in the system when making this
adjustment. Stop the pump and remove the nozzle closest to
the pressure transducer leaving the valves open on boom
sections.
value is calculated.
pressure transducer is replaced and on initial usage.
tractor is moving.
SETUP / 7