Dickson HT125 Руководство - Страница 5

Просмотреть онлайн или скачать pdf Руководство для Регистраторы данных Dickson HT125. Dickson HT125 12 страниц. High-temp logger operation

Dickson HT125 Руководство
DicksonWare™ Software Specifications
Microsoft Windows® compatible
Allows for simple viewing and zooming of logged data
Easy set-up of Dickson Data Loggers including:
User selectable sample intervals from 10 seconds to 24 hours
Display temperature in °C or °F
Delayed logger start times
Logger data capacity can be set to wrap data or stop when full
Allow for real time monitoring and graphing.
Effortless exporting of data and graphs to other software
Data can be viewed in tabular (numeric/table) or graphical formats
Fast downloading of logged data - 30 seconds (typical) from full logger
Even shows battery power status for battery operated loggers
Specifications:
Compatible With: Microsoft Windows® 95, 98, 2000, NT & XP
PC Requirements: PC with 386 MHz or better microprocessor, 4 M RAM, 1 free COM (serial) port,
CD drive
Cable Type/Length: 9 pin male D-shell to male 2.5mm stereo plug, 6' long
Computer Interface: RS-232 COM (serial) port
DicksonWare™ Version Required (minimum): See Specific Model for Version Requirement
DicksonWare™ SECURE Software Specifications
To ensure the authenticity, integrity and confidentiality of data, 21CFR Part 11 requires that electronic
records adhere to certain criteria. DicksonWare™ SECURE software collects data from our validated data
logger, creates detailed graphs and reports and contains the following features that comply with 21CFR11:
Password protection
Electronic signature consisting of User ID and Password
Collected data encrypted in secure files
Audit trail capability to identify date, time, user and action
For a complete 21CFR11 compliant package, order the following:
1.
Appropriate Validated data logger
DicksonWare™ SECURE Software & Serial Download Cable - A025
2.
3.
Certificate of Validation/logger - N520
4.
Choose One Calibration Option Listed Below:
a.
NIST Traceable Calibration 3-pt. (new unit) - N300
b.
NIST Traceable Calibration 1-pt. (new unit) - N100
c.
A2LA Accredited Calibration 3-pt. (new unit) - N400
Note: SW400 Calibration Software may not be used with DicksonWare™ SECURE software.
Specifications:
Compatible With: Windows® 95, 98, 2000, NT & XP
PC Requirements: 386MHz processor or higher, 4MB RAM, 1 free COM (serial) port, CD drive
Cable Type/Length: 9 pin male D-shell to male 2.5mm stereo plug, 6" long
Operating Range: -20 to +135˚F, 0 to 95%RH (non-condensing)
Computer Interface: RS-232 COM (serial port)
Rev. 07/07