Dickson THDx Руководство - Страница 8
Просмотреть онлайн или скачать pdf Руководство для Диктофон Dickson THDx. Dickson THDx 9 страниц. Temperature, humidity & dew point recorder
Troubleshooting
Problem
Temperature Pen & Display do not match
Instrument is not responding to key presses
Instrument turns off
Probe exposed to environments exceeding
95%RH for extended period
Alarm symbol is flashing in digital display
Display shows dc and indicator on the left
part of the digital display
Display shows E (lower left of digital display)
Out of calibration or questionable accuracy
Display won't light up
Unit won't work at all
Pen trace too fine or absent
Display shows Err
Display shows Prob
Display shows cold
Display shows frozen
Factory Service & Returns
We recommend that damaged instruments be returned
to our factory for complete repair. Before returning
any instrument or package, please call for a Return
Authorization (RA) number. When calling, please have
the following information available:
1.
P.O. number for out-of-warranty units.
2. Serial number of unit.
The Dickson Warranty
Dickson warrants the TH6 line of instruments will be
free from defects in material and workmanship
for a period of twelve months after
normal use and service
delivery. In the event of a claim under this warranty,
the product or part must be returned to the factory for
repair or replacement (shipping prepaid) with a Return
Authorization Number (See repair information above). It
will be repaired or replaced at Dickson's option without
charge.
Solution
• Check dip switch setting & proper chart
• May also be hysteresis, see page 4, "Pens"
• Need for pen adjustment, see page 4, "Pen Adjust"
• Keypad may be locked, check dip switch #8
• Slower, firmer key presses (may take multiple presses)
• Check AC adapter connection (widen prongs of adapter to
fit together)
• Display may be off, check dip switch #7
• Probe should be dried out under normal ambient conditions –
time required varies on temperature, RH and air flow
• Alarm sounds audibly for 60 seconds if out of range conditions
occur, then indicator will flash until alarm key is depressed and
alarm is reset (depress MIN/MAX keys for information)
• Factory repair is necessary, send to Dickson for repair
• System error or error in calibration, send to Dickson
• Instrument exposed to harsh environments or stressful
conditions, see "Calibration" procedure in manual
• Return to factory for re-calibration
• Check dip switch #7, switch should be off
• Check both dip switch #7 & #8. Both should be off to
allow operation
• Pen may need to be replaced, moistened, or sanded
• Remove pen cap
• Temperature being monitored is too high, see pg. 2
• Temperature being monitored is extremely cold or probe
is disconnected
• Temperature being monitored is too low, see pg. 2
• Reset the unit by shutting it down (unplug the AC adapter and
take the batteries out) then restore power source and turn it on
3. Model number of unit.
4. The problem you're experiencing with unit.
Clearly mark the RA number on the outside of
the package and return the instrument, shipping
prepaid. Delivery will be refused for packages
sent without RA numbers.
This warranty does not cover routine calibration, pen,
chart and battery replacement. The foregoing warranty
under
and remedy are exclusive and in lieu of all other warran-
ties either expressed or implied. Dickson shall not be
liable for consequential or incidental damages resulting
from failure or malfunction of its products. Dickson
makes no warranty for products not manufactured by
it or for any products modified by buyer, or subject to
misuse or neglect.
8