EPC NEV Controller Техническое справочное руководство - Страница 6
Просмотреть онлайн или скачать pdf Техническое справочное руководство для Контроллер EPC NEV Controller. EPC NEV Controller 20 страниц. Dc motor speed control
SPECIAL NOTICE
Always verify that NO HIGH VOLTAGE POTENTIAL is present on the 12 volt
battery/power supply terminals. This can be dangerous to anyone servicing or using the
equipment.
Testing for this condition can be done as follows:
Connect a high voltage meter between each 12 volt battery terminal (or power supply)
and each high voltage battery terminal. The meter should read close to zero volts in all
cases.
For automotive applications, also check the voltage potential between the chassis/frame
of the vehicle and each high voltage battery terminal. The meter should read close to
zero volts in all cases.
If there is a high voltage leak anywhere in the system, it must be repaired immediately.
All EPC controllers are fully isolated, and cannot leak voltage into the 12-volt system.