Epcom PROAUDIO SF-4120UC Руководство по эксплуатации - Страница 10

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Усилитель Epcom PROAUDIO SF-4120UC. Epcom PROAUDIO SF-4120UC 20 страниц. Class d power amplifier

5. OPERATION ILLUSTRATION
7. Speaker Connection
Before turning on the device, please carefully confirm that the load is constant-voltage or
constant-impedance speakers and set the amplifier to the corresponding output mode. It is
forbidden to switch the constant voltage and constant impedance state arbitrarily when the
power is on.
Constant voltage mode: Turn the switches corresponding to CH1/CH2: 4-16Ω and CH3/CH4:
4-16Ω to OFF.
Constant impedance mode: Turn the switches corresponding to CH1/CH2: 4-16Ω and CH3/CH4:
4-16Ω to ON.
The operation method is as follows:
① When the 100V and 4-16Ω speaker output
mode selection switch is set to the 100V
position, as shown in the figure below:
100V/4-16Ω
OUTPUT
CH2
CH1
-
-
+
+
SPK+
100V voltage speaker
8. Audio source priority
EMC >MUTE >REMOTE MIC >INPUT1-4 >LINE1-2。
9. Method of making network connection line
1 2 3 4 5 6
A
A: 1 Blue 2 White-Blue 3 Brown 4 White-Brown 5 Orange 6 White-Orange 7 Green 8 White-Green
B: 1 Blue 2 White-Blue 3 Brown 4 White-Brown 5 Orange 6 White-Orange 7 Green 8 White-Green
Note: The color of cable is not specified. A=B is satisfied.
◆ Remote micrphone cable sequence:
1 MIC485-N
5 GND
2 MIC485-P
6 +24V
3 +24V
7 MIC INPUT+
4 GND
8 MIC INPUT-
SPK-
7 8
10
②When the 100V and 4-16Ω speaker output
mode selection switch is set to the 4-16Ω
position, as shown in the figure below:
100V/4-16Ω
OUTPUT
CH2
CH1
-
+
+
SPK+
4Ω constant impedance speaker
1 2 3 4 5 6 7 8
◆ Remote volume control cable sequence:
1 PAN485-N
5 GND
2 PAN485-P
6 +24V
3 +24V
7 GND
4 GND
8 GND
-
SPK-
B