Epever LS1024B Краткое руководство по эксплуатации - Страница 2

Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Контроллер Epever LS1024B. Epever LS1024B 2 страницы. Solar charge controller
Также для Epever LS1024B: Руководство пользователя (2 страниц)

Epever LS1024B Краткое руководство по эксплуатации
HUIZHOU EPEVER TECHNOLOGY CO., LTD.
A. Over Voltage Disconnect Voltage > Charging Limit Voltage ≥ Equalize Charging
Voltage ≥ Boost Charging Voltage ≥ Float Charging Voltage > Boost Reconnect
Charging Voltage.
B. Over Voltage Disconnect Voltage > Over Voltage Reconnect Voltage.
C. Low Voltage Reconnect Voltage > Low Voltage Disconnect Voltage ≥ Discharging
Limit Voltage.
D. Under Voltage Warning Reconnect Voltage > Under Voltage Warning Voltage ≥
Discharging Limit Voltage.
E. Boost Reconnect Charging voltage > Low Voltage Disconnect Voltage.
CAUTION: Please refer to the user manual or contact the sales for the
details of the setting operation.
(2) Load Set Mode
1) Manual Control(default ON)
The load is turned ON/OFF via the button or remote command.
2) Light ON/OFF
3) Light ON/OFF + Timer
4)Time Control
Control the load on/off time by setting a real-time clock.
6 Protections
 PV over current
When the charging power of the PV array exceeds its rated charging power, it will be
charged at the rated charging power.
PV short circuit
The controller will stop charging when the input terminal of the PV array is short-
circuited. After clearing the faults, the charging will resume automatically.
PV reverse polarity
When the polarity of the PV array is reversed, the controller may not be damaged and
can continue to operate normally after the polarity is corrected.
Battery reverse polarity
When the polarity of the battery is reversed, the controller may not be damaged and
can continue to operate normally after the polarity is corrected.
 Battery over voltage
When the battery voltage reaches the over voltage disconnect voltage, the controller
will automatically stop charging the battery to prevent battery damage caused by over-
charging.
Battery over discharge
When the battery voltage reaches the low voltage disconnect voltage, the controller will
automatically stop discharging the battery to prevent battery damage caused by over-
discharging. (Any controller connected loads will be disconnected. Loads directly
connected to the battery will not be affected and may continue to discharge the
battery.)
Battery over temperature
The controller detects the battery temperature through an external temperature sensor.
The battery will stop working when its temperature exceeds 65 °C and resume when its
temperature is below 55 °C.
Overload
When the load current is higher than 1.05 times the rated discharge current, the
controller will automatically cut off the output. After the load reconnects automatically
five times (delay of 5s, 10s, 15s, 20s, 25s), please reduce the electrical equipment. And
then press the load ON/OFF button or restart the controller or wait for one night-day
cycle (night time > 3 hours) to eliminate the overload fault.
Load short circuit
When the load is short-circuited (The short circuit current is higher than or equal to 2
times the rated discharge current), the controller will automatically cut off the output.
After the load reconnects automatically five times (delay of 5s, 10s, 15s, 20s, 25s),
please press the load ON/OFF button, or restart the controller, or wait for one night-day
cycle (night time > 3 hours). Then the load reconnection automatically will resume.
Turn-On voltage (Adjustable):
5V(12Vsystem), delay10min. Turn-Off
voltage (Adjustable):
6V(12Vsystem), delay10min.
Note: 24V system voltage×2
3
Tel:+86-10-82894896/82894112/+86-752-3889706
Controller over temperature
An internal temperature sensor can detect the internal temperature of the controller.
The controller stops working when its internal temperature exceeds 85 °C and resumes
when the internal temperature is below 75 °C.
TVS high voltage transients
The internal circuitry of the controller is designed with Transient Voltage Suppressors
(TVS), which can only protect against the high-voltage surge pulses with less energy. If
the controller is to be used in an area with frequent lightning strikes, it is recommended
to install an external surge arrester.
7 Troubleshooting
Faults
When there is sufficient
direct sunlight on the PV
array, the charging indicator
does not light up.
The wire connection is
correct, but the controller is
not working.
Battery green indicator fast
flashing
Battery red indicator on
solid
Battery red indicator slowly
flashing
Charge, Load and
Battery(orange)indicator
flashing
Load red indicator slowly
flashing
Load red indicator fast
flashing
8 Technical Specifications
Item
System nominal voltage
Battery type
Rated charge current
Rated discharge current
Working voltage range of
controller
Max. PV open circuit
voltage
Self-consumption
Charge circuit voltage
drop
Discharge circuit voltage
drop
Temperature
compensate coefficient
Working environment
temperature
Relative humidity
Enclosure
Grounding
Dimension(mm)
138.6x69.3x37
Mounting size
Mounting hole size
Terminal
Weight
9 Disclaimer
This warranty does not apply under the following conditions:
 Damage from improper use or use in an unsuitable environment.
 PV or load current, voltage, or power exceeds the rated value of the controller.
 The controller's working temperature exceeds the limit working environment
temperature.
 User disassembly or attempted to repair the controller without permission.
 The controller is damaged due to natural elements such as lighting.
 The controller is damaged during transportation and shipment.
Any changes without prior notice! Version number:V3.2
Website:www.epever.com
Possible reasons
Troubleshooting
PV array
Confirm that PV and battery wire
disconnection
connections are correct and tight
Please check the voltage of the
Battery voltage is
battery. At least 8V voltage to
lower than 8V
activate the controller.
Check
whether
Battery over
voltage is higher than OVD (over
voltage
voltage disconnect voltage), and
disconnect the PV.
Waiting for the battery voltage
restore to or above LVR (low
Battery over
voltage reconnect voltage) or
discharged
changing the power supply in
other ways.
When the battery temperature
Battery over
declines to be below 55 ºC, the
temperature
controller will resume.
When the heat sink of the
controller exceeds 85 ℃ , the
Controller over
controller will automatically cut off
temperature
the input and output circuit. When
the temperature bellows to 75℃,
the controller will resume work.
① Please reduce the number of
electric equipment.
② Restart the controller or press
Overload
the load ON/OFF button.
③ Wait for one night-day cycle
(night time>3 hours).
① Check carefully loads
connection, clear the fault.
② Restart the controller or press
Load short circuit
the load ON/OFF button.
③ Wait for one night-day cycle
(night time>3 hours).
LS1024B
LS2024B
12/24VDC Auto
Sealed/Gel/Flooded/User
10A
20A
10A
20A
8~32V
50V
≤8.4mA/12V;≤7.8mA/24V
≤0.28V
≤0.20V
-3mV/℃/2V (default)
-35℃~+50℃
≤95% (N.C.)
IP30
Common positive
159.6x81.4x47.8
126mm
147x50mm
Φ4.3
Φ4.3
2
2
4mm
10mm
0.13kg
0.3kg
4
the
battery
LS3024B
30A
30A
200.6x101.3x57
190x70mm
Φ4.5
2
10mm
0.5kg