2. Warning before use:
Make sure you read the instructions manual
Once you remove the packaging, you need to inspect whether the furnace is complete in terms of
the basic elements, and whether the fire-resistant glass on the front side is in good condition.
3. Description of the Furnace
The furnace is designed to allow efficient combustion of solid fuel with the option to adjust and regulate
the necessary amount of air for the combustion process.
When it comes to construction, the furnace is different compared to other solid fuel furnaces in terms of
both its design and the composition of certain elements. It is made out of sheet metal and cast, which
make it very easy to maintain and clean. The outer shell is enamelled or painted.
The combustion chamber is made of sheet metal, and it is coated with cast positions on the inside. On
the front side of the furnace, there is a fire resistant glass with mirror effect. You can see the flame
through the middle glass, which produces a special effect while heating up the room. Also, there is the
combustion door on the right side of the furnace, which when left open in turn opens the lateral middle
right side of the furnace. Lateral middle right side is connected to the chamber with a hinge and a right
batten. The closed lateral middle right side is connected to the chamber with a magnet.
Opening and closing of the lateral right side combustion door is done using a special wrench, by lifting
the handle and placing the wrench cogwheel into the handle opening.
In the middle part of the furnace, there are two pieces of glass with fireproof interior and exterior areas,
and decorative mirror effect. The inner glass is on the front door of the furnace that is not being used.
When replacing the inner glass in a special case, when cleaning the inner glass or when removing the
residue, you should remove the burner, cap, lateral left and right sides, upper glass with the mirror effect
and the middle glass with the mirror effect (Figure 1). We have reached the front door, which can be
opened and leaned against the front of the furnace, and we can replace the glass, clean the soot from the
glass, and if needed, remove the residue.
Under the ash tray cover (Figure 1, position 1), there are two air controllers for regulation of required
amount of combustion air.
Fig. 2
The ash tray is bolted with an interlock and can be pulled out using a special wrench (see Fig. 2) by
placing the prism top into the ash tray holder.
At the back side of the furnace, there is a chimney plug with a throttle shaft and a throttle that regulates
the airflow. The throttle position is fixed to the shaft using a spring, thus retaining the airflow. The
maximum airflow in the furnace is achieved when the throttle shaft is in a horizontal position, while the
minimum airflow is achieved when the throttle shaft is in a vertical position. The necessary airflow in the
chimney is 10 Pa (1 mm VS) at minimum.