Axis 25205 Руководство - Страница 8
Просмотреть онлайн или скачать pdf Руководство для Аксессуары для фотоаппаратов Axis 25205. Axis 25205 8 страниц. Outdoor housing
Maintenance
Annual maintenance is required to inspect all visible seals for wear and damage. Worn or
damaged seals should be replaced.
Recommendation:
Treat all visible seals with silicone at least once a year to prevent them
from drying out and to aid opening and closing of the housing. Use an all-purpose silicone
spray for use on electrical equipment and components, and also compatible with rubber,
metal and plastic materials.
Clean the housing with a damp cloth only (not on the window). Do not use chemicals to
clean the housing as this may affect the powder coat finish. The window should only be
cleaned with a dry cloth.
Burnt fuses in the fused terminal block can be replaced to reinstate the power supply of the
camera. Use a 5A, 250 V AC fuse and ensure that the mains is disconnected before
beginning.
Specifications
Weight
Power requirements
Approx. 6 lbs
AXIS 290B Power adapter (included):
(2,75 kg)
Input voltage: 100-240 (50/60HZ) VAC
Input current Max 1.2A
Max Output Power 50W
Output voltage 15 VDC
Output current 3.4 A
IMPORTANT!
Power adapter is for indoor use only!
AXIS 290B Housing:
Input voltage: 9-15 V DC
Input current:
Max 2.8A at 9V, 3A at 12V, 3.5A at 15V
Specifications may change without prior notice.
290B Outdoor housing
INSTAL GUIDE HOUSING ENV WHITE
Date: July 2005
Operating temperature
-4F to 108F (-20°C to +42°C)
Warning: The housing should
not be exposed to many hours
of direct sunlight as this may
overheat and damage the
camera beyond repair. The
maximum temperature inside
the housing should never
exceed 122F (50°C).
r3.0
COPYRIGHT AXIS COMMUNICATIONS AB 2005
25205
PART NO.