Olympus BX51 Руководство по эксплуатации - Страница 28

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Микроскоп Olympus BX51. Olympus BX51 40 страниц. System
Также для Olympus BX51: Руководство по эксплуатации (17 страниц), Руководство по эксплуатации (34 страниц), Руководство по эксплуатации (37 страниц), Руководство по эксплуатации (11 страниц)

Olympus BX51 Руководство по эксплуатации

SPECIFICATIONS

Item
1. Optical system
2. Illumination
3. Focusing
4. Revolving nosepiece
5. Observation tube
6. Stage
24
UIS2/UIS (Universal Infinity System) optical system (featuring infinity correction)
Built-in transmitted Koehler illumination
12V, 100W long-life halogen bulb (pre-centered) 12V100WHAL-L (PHILIPS 5761) or 12 V, 50 W
long-life halogen bulb (pre-centered) 12V50WHAL-L (LIFE JC)
(Average life time: Approximately 2,000 hr. when used as directed)
Light intensity voltage range: 2 V or less to 12.0 V DC (continuous)
Light intensity preset button (voltage adjustment range: 2 V or less to 12.0 V DC)
Rated voltage: 100-120/220-240 V
Power consumption: 140 W
Stage height movement by roller guide (rack & pinion)
Stroke per rotation: 0.1 mm (fine), 17.8 mm (coarse)
Full stroke range: 25 mm
Upper limit stopper
Tension adjustment on coarse focus adjustment knob
U-5RE-2
Type
5-position revolv-
ing nosepiece
Installable mod-
None
ules
Type
U-BI30-2
Widefield binocu-
lar tube
Field No.
Tube inclination
30°
I n t e r p u p i l l a ry
distance adjust-
ment
Light path selec-
tor
Type
Common-axis knobs on bottom right Common-axis knobs on bottom left
Size
Movement
X- and Y-axis knobs with adjustable tension
mechanism
Movement range: 52 mm in vertical (Y) direction, 76 mm in horizontal (X)
direction
Specimen hold-
ers (single slide
holder)
Specimen hold-
U-HLDT-4 (left opening, thick slide holder)
ers (double slide
U-HLD-4 (left opening, thin slide holder)
holder)
Specification
, 1.8/0.8 A, 50/60 Hz
U-D6RE
Universal 6-posi-
Universal 7-posi-
tion revolving
tion revolving
nosepiece
nosepiece
Transmitted DIC prism,
transmitted light analyzer
U-TBI3
U-TR30-2
Widefield tilting
Widefield trinocu-
binocular
lar tube
22
5°-35°
continuous
50 mm to 76 mm
None
U-SVRB-4
Rectangular ceramic-coated, wire-driven stage
156 mm (D) x 191 mm (W)
U-HLST-4 (thick slide holder)
U-HLS-4 (thin slide holder)
U-HRDT-4 (right opening, thick slide holder)
U-HRD-4 (right opening, thin slide holder)
U-D7RE
U-P6RE
Universal 6-posi-
tion centered
revolving nose-
piece
U-SWTR-3
U-TR30NIR
Super widefield
trinocular
26.5
30°
3 steps: @ BI 100%
² BI 20%, Photo 80%
BI 50%, Photo 50%
for U-TR30NIR only
³ Photo 100%
U-SVLB-4