1. Display shows the OUTPUT mode.
Output current
0.0 A
0 %
Torque
OUTPUT
2. Set the control mode to local by pressing and
/2&
holding the
button until "
# %
displayed. After releasing the button text
appears on the display.
0.0 A
0 %
OUTPUT
3. The following ACS 400 parameters must be
set:
9901
LANGUAGE
9905
MOTOR NOM VOLT
9906
MOTOR NOM CURR
9907
MOTOR NOM FREQ
9908
MOTOR NOM SPEED
9909
MOTOR NOM POWER
ϕ
9910
MOTOR COS
Motor is now ready to run.
Press START/STOP button to turn on motor.
Note! Before increasing motor speed, check that the motor
is running in desired direction.
To set the reference:
•To increase the reference press
•To decrease reference press
To stop motor press
Note! Always disconnect mains supply before working on ACS 400 or motor.
Frequency
0.0 Hz
reference
Output frequency
0.0 Hz
REM
LOCAL CONTROL
LOC
0.0 Hz
0.0 Hz
LOC
.
.
button.
11
4. Instructions for setting the parameters:
•Press
to enter the Menu. MENU flag
&
becomes visible.
•Press
%#
to select the start-up group (99).
" is
•Select the parameter with
•Press
%#
to get to the parameter set mode.
•Alter the value by using
•Store the modified value by pressing
5. After setting all start-up parameters press
button twice to resume OUTPUT display.
6. For further information, refer to User's Manual.
12
13
99 START-UP DATA
LOC
MENU
9901 LANGUAGE
ENGLISH
MENU
LOC
and
9901 LANGUAGE
DEUTSCH
LOC
and
buttons.
%#
forward
direction
reverse
direction
buttons.
.
&