Axor Citterio Руководство по эксплуатации - Страница 3
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Сантехника Axor Citterio. Axor Citterio 12 страниц.
Также для Axor Citterio: Установка/Инструкции пользователя/Гарантия (16 страниц), Руководство по установке (16 страниц), Руководство (4 страниц), Инструкции по эксплуатации/инструкции по сборке (12 страниц)
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
F A U L T
⁄ Mixer stiff
⁄ Mixer dripping
⁄ Water escaping at the threaded base
⁄ Hot water temperature too low
A S S E M B L Y (see page 04)
S Y M B O L D E S C R I P T I O N
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
max. 70°C ⁄ 4 min
C A U S E
⁄ Cartridge defective, calcified
⁄ Cartridge defective
⁄ connection hoses not completely screwed into basic body
⁄ O-ring at the connection hose defective.
⁄ Hot water limiter incorrectly set
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 06)
To adjust the hot water limiter. Using a hot water limiter in combination with a
continuous flow water heater is not recommended.
O P E R A T I O N (see page 07)
⁄ Hansgrohe recommends not to use as drinking water the first half liter of
water drawn in the morning or after a prolonged period of non-use.
⁄ Do not rotate the spout further than 360º or damage to the hose will
result.
C L E A N I N G (see page 07 and enclosed brochure)
If the waterflow drops, clean the filter located between hose and handspray.
M A I N T E N A N C E (see page 07)
The check valves must be checked regularly according to DIN EN 1717 in
accordance with national or regional regulations (at least once a year).
D I M E N S I O N S (see page 09)
F L O W D I A G R A M (see page 09)
Normal spray
Regular
S P A R E P A R T S (see page 10)
S P E C I A L A C C E S S O R I E S (order as an extra)
service tool #95910000 (see page 10)
R E M E D Y
⁄ Exchange cartridge
⁄ Exchange cartridge
⁄ Tighten connection hoses by hand
⁄ Exchange O-ring
⁄ Set hot water limiter
0 3
EN