Arc-Zone Neutra LTG Руководство по эксплуатации - Страница 4

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Шлифовальный станок Arc-Zone Neutra LTG. Arc-Zone Neutra LTG 7 страниц. Tungsen grinder

Initial Set-Up and Operation

Place the grinder on a flat surface with enough free space on each side for proper ventilation and
to allow you to comfortably prepare electrodes.
With the power switch in the OFF position and the grinder unplugged proceed as follows:
Your new Neutra LTG does not contain grinding fluid upon delivery and must be filled prior to
operation with the supplied grinding fluid.
Fill the grinding chamber with the grinding fluid provided using the hose #26 on the left side of the
grinder (see Fig. 1). Fill the to the MAX line shown on the inspection cover frame #9 (See Fig. 2).
Figure 2 : ArcTime™ LTG (Side view)
Electrode Grinding Procedure
GRINDING A TIP-FLAT ON THE ELECTRODE
Tighten the electrode in the electrode holder. Insert the electrode and electrode holder into position
"C" (See Fig. 3) in the console #24 (Fig. 1). Using very light pressure feed the electrode in until
it contacts the grinding wheel. Remove and check for desired tip-flat.
Arc-Zone.com, Inc. • 1331 Specialty Dr • Vista, CA 92081 • Tel. 1.760.931.1500